A comparison of the relative biological effectiveness of low energy electronic brachytherapy sources in breast tissue: a Monte Carlo study
- 16 December 2015
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (1) , 383-399
Abstract
Electronic brachytherapy sources use low energy photons to treat the tumor bed during or after breast-conserving surgery. The relative biological effectiveness of two electronic brachytherapy sources was explored to determine if spectral differences due to source design influenced radiation quality and if radiation quality decreased with distance in the breast. The RBE was calculated through the number of DNA double strand breaks (RBE DSB ) using the Monte Carlo damage simulator (MCDS) in combination with other Monte Carlo electron/photon spectrum calculations. 50kVp photons from the Intrabeam (Carl Zeiss Surgical) and Axxent (Xoft) through 40-mm spherical applicators were simulated to account for applicator and tissue attenuation in a variety of breast tissue compositions. 40kVp Axxent photons were also simulated. Secondary electrons (known to be responsible for most DNA damage) spectra at different distance were inputted into MCDS to calculate the RBE DSB . All RBE DSB used a cobalt-60 reference. RBE DSB data was combined with corresponding average photon spectrum energy for the Axxent and applied to model-based average photon energy distributions to produce an RBE DSB map of an accelerated partial breast irradiation (APBI) patient. Both Axxent and Intrabeam 50kVp spectra were shown to have a comparable RBE DSB of between 1.4 and 1.6 at all distances in spite of progressive beam hardening. The Axxent 40kVp also demonstrated a similar RBE DSB at distances. Most RBE DSB variability was dependent on the tissue type as was seen in rib (RBE DSB ≈ 1.4), gland (≈1.55), adipose (≈1.59), skin (≈1.52) and lung (≈1.50). RBE DSB variability between both sources was within 2%. A correlation was shown between RBE DSB and average photon energy and used to produce an RBE DSB map of a dose distribution in an APBI patient dataset. Radiation quality is very similar between electronic brachytherapy sources studied. No significant reductions in RBE DSB were observed with increasing distance from the source.Keywords
Funding Information
- Xoft, a subsidary of iCad
This publication has 46 references indexed in Scilit:
- Induction and Repair of Clustered DNA Lesions: What Do We Know So Far?Radiation Research, 2013
- Accelerated Partial Breast Irradiation: A Review and Description of an Early North American Surgical Experience with the Intrabeam Delivery SystemCancer Control, 2012
- In Vivo Dosimetry for Single-Fraction Targeted Intraoperative Radiotherapy (TARGIT) for Breast CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Estimation of the RBE of mammography-quality beams using a combination of a Monte Carlo code with a B-DNA geometrical modelPhysics in Medicine & Biology, 2011
- Tissue modeling schemes in low energy breast brachytherapyPhysics in Medicine & Biology, 2011
- Accelerated partial breast irradiation: Initial experience with the Intrabeam SystemSurgical Oncology, 2011
- Effects of oxygen on intrinsic radiation sensitivity: A test of the relationship between aerobic and hypoxic linear-quadratic (LQ) model parametersa)Medical Physics, 2006
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Initial Events in the Cellular Effects of Ionizing Radiations: Clustered Damage in DNAInternational Journal of Radiation Biology, 1994
- Enhanced risk from low-energy screen—film mammography X raysBritish Journal of Radiology, 1989