Optimizing Calibration for a Capacitance-Based Void Fraction Sensor with Asymmetric Electrodes under Horizontal Flow in a Smoothed Circular Macro-Tube
Open Access
Abstract
In this study, a technique that uses a capacitance sensor with an asymmetric electrode to measure the void fraction of a refrigerant was developed. It is known that the void fraction and flow pattern affect the measured capacitance. Therefore, the relationship between the void fraction and capacitance is not linear; hence, a calibration method for obtaining accurate measurements is necessary. A calibration method was designed in this study based on repeated capacitance measurements and the bimodal temporal distribution to calibrate the atypical and repetitive flow patterns of slug flow and its transition to the intermittent flow regime. The calibration method also considers the weighted-average relation for the gradual transition of the intermittent to annular flow pattern according to the change from low to high quality. The proposed method was experimentally analyzed under the conditions of R32 refrigerant, a tube inner diameter of 7.1 mm, saturation temperature of 25 °C, mass flux of 100–400 kg m−2 s−1, and vapor quality of 0.025–0.900, and it was validated using a quick-closing valve (QCV) system under identical conditions. A relative error of 2.99% was obtained for the entire system, indicating good agreement between the proposed and QCV-based methods.Keywords
Funding Information
- New Energy and Industrial Technology Development Organization (JPNPP18005)
This publication has 19 references indexed in Scilit:
- Flow regime based calibration of a capacitive void fraction sensor for small diameter tubesInternational Journal of Refrigeration, 2013
- Mapping of horizontal refrigerant two-phase flow patterns based on clustering of capacitive sensor signalsInternational Journal of Heat and Mass Transfer, 2010
- Characterization of diabatic two-phase flows in microchannels: Flow parameter results for R-134a in a 0.5mm channelInternational Journal of Multiphase Flow, 2006
- Investigation of flow boiling in horizontal tubes: Part I—A new diabatic two-phase flow pattern mapInternational Journal of Heat and Mass Transfer, 2005
- An investigation on void fraction of vapor–liquid two-phase flow for smooth and microfin tubes with R134a at adiabatic conditionInternational Journal of Multiphase Flow, 2004
- Interfacial measurements in stratified types of flow. Part II: Measurements for R-22 and R-410AInternational Journal of Multiphase Flow, 2004
- The effect of void fraction model on estimation of air conditioner system performance variables under a range of refrigerant charging conditionsInternational Journal of Refrigeration, 1994
- A capacitance sensor for two-phase void fraction measurement and flow pattern identificationInternational Journal of Multiphase Flow, 1988
- Flow pattern, void fraction and pressure drop of refrigerant two-phase flow in a horizontal pipe—I. Experimental dataInternational Journal of Multiphase Flow, 1983
- Calculation of void volume fraction in the subcooled and quality boiling regionsInternational Journal of Heat and Mass Transfer, 1970