Creation and description of sand blasted stamp created micro roughness on polyetheretherketone with subsequent physical vapor deposition coating for promotion of osseointegration
- 26 October 2018
- journal article
- research article
- Published by Wiley in Materialwissenschaft und Werkstofftechnik
- Vol. 49 (11) , 1301-1313
Abstract
Adjusting the topography of implant surfaces on a micro‐scale allows improvement of osseointegration. Titanium surface modification like sand blasting is one of the known methods to alter the topography of the surface. Polyetheretherketone as a biomaterial is a suitable alternative to titanium but exhibits an inert surface character. The aim of this study was to combine the positive bulk properties of polyetheretherketone with the positive surface properties of sand blasted titanium. For the creation of particle free structured polyetheretherketone surface, four different sand blasted die were pressed on counter die polyetheretherketone to transfer the structure. Furthermore, a titanium layer was applied on the surface using physical vapor deposition. The transfer process of the four different topographies was investigated with roughness measurements and scanning electron microscope. One topography, created with aluminum oxide particles on copper, was found with the required Ra value of 1 μm and Rz value of 9.2 μm for improved osseointegration.Keywords
Funding Information
- Central Innovation Program for small and medium-sized enterprises (KF2012469CR4)
This publication has 29 references indexed in Scilit:
- The in vitro response of human osteoblasts to polyetheretherketone (PEEK) substrates compared to commercially pure titaniumBiomaterials, 2008
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007
- Internal plate fixation of fractures: short history and recent developmentsJournal of Orthopaedic Science, 2006
- Polyetheretherketone as a biomaterial for spinal applicationsBiomaterials, 2006
- In vitro apatite formation and its growth kinetics on hydroxyapatite/polyetheretherketone biocompositesBiomaterials, 2005
- Influence of interphase layer on the overall elasto-plastic behaviors of HA/PEEK biocompositeBiomaterials, 2004
- Ultrastructural characterization of the implant/bone interface of immediately loaded dental implantsBiomaterials, 2004
- Understanding Peri‐Implant Endosseous HealingJournal of Dental Education, 2003
- Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigsJournal of Biomedical Materials Research, 1991
- Potential of polyetheretherketone (PEEK) and carbon-fibre-reinforced PEEK in medical applicationsJournal of Materials Science Letters, 1987