Myocardial Arterial Spin Labeling with Double Inversion Recovery for reduced physiological noise
Open Access
- 11 August 2025
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (6) , 2460-2474
Abstract
Purpose: To introduce Double Inversion Recovery (DIR) preparations for myocardial Arterial Spin Labeling (myoASL) for mitigation of heart rate (HR) variability induced physiological noise (PN).Methods: DIR‐labeling was implemented for double ECG‐gated myoASL‐sequences and compared with conventional Flow‐sensitive Alternating Inversion Recovery (FAIR) labeling using single inversions. In DIR‐preparations, the FAIR‐inversion pulses were immediately followed by an identical reinversion pulse, applied either slice‐selectively or nonselectively. Bloch‐equation‐based simulation and phantom experiments were performed to evaluate the PN and SNR across a range of HR variabilities. Data from six healthy subjects were acquired to evaluate myocardial blood flow (MBF), PN, and SNR in vivo.Results: Simulation experiments showed that the average MBF values remained nearly constant across the range of HR variabilities and were comparable across all three sequences. However, DIR‐labeling allowed for greater recovery of the myocardial background signal, which mitigates the sensitivity to HR‐dependent changes in the inversion time. Consequently, PN in the presence of HR variability was substantially reduced with DIR‐labeling. For HR variabilities corresponding to the mean value observed in vivo, this resulted in a simulated SNR gain of 1.79 0.90 for selective and 1.55 0.77 for nonselective DIR‐labeling. In vivo, DIR‐labeling showed reduced PN, with 53% ()/44% () less PN compared with conventional FAIR‐myoASL, leading to an average SNR gain of 1.47 0.63 ()/1.32 0.57 () with selective/nonselective reinversions.Conclusion: The proposed DIR‐preparations reduce sensitivity to HR variations and alleviate PN in double ECG‐gated myoASL, improving the precision of myoASL‐based perfusion quantification.Keywords
Funding Information
- European Research Council (101078711)
- ZonMw (04510011910073)
- Hartstichting (03‐004‐2022‐0079)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (STU.019.024)
This publication has 49 references indexed in Scilit:
- Comparison of Myocardial Blood Flow Quantification Models for Double ECG Gating Arterial Spin Labeling MRI: Reproducibility AssessmentJournal of Magnetic Resonance Imaging, 2024
- Black‐Blood Contrast in Cardiovascular MRIJournal of Magnetic Resonance Imaging, 2020
- Quantification of Myocardial Perfusion With Vasodilation Using Arterial Spin Labeling at 1.5TJournal of Magnetic Resonance Imaging, 2020
- Quantitative myocardial perfusion in coronary artery disease: A perfusion mapping studyJournal of Magnetic Resonance Imaging, 2019
- Robust motion correction for myocardial T1 and extracellular volume mapping by principle component analysis‐based groupwise image registrationJournal of Magnetic Resonance Imaging, 2017
- On the transient phase of balanced SSFP sequencesMagnetic Resonance in Medicine, 2003
- Determination of regional blood volume and intra‐extracapillary water exchange in human myocardium using Feruglose: First clinical results in patients with coronary artery diseaseMagnetic Resonance in Medicine, 2002
- Measurement of human myocardial perfusion by double-gated flow alternating inversion recovery EPIMagnetic Resonance in Medicine, 1999
- Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mappingMagnetic Resonance in Medicine, 1995
- Multiple inversion recovery reduces static tissue signal in angiogramsMagnetic Resonance in Medicine, 1991