Evaluation of six nucleic acid amplification tests used for diagnosis ofNeisseria gonorrhoeaein Russia compared with an international strictly validated real-timeporApseudogene polymerase chain reaction
- 8 October 2009
- journal article
- research article
- Published by Wiley in Journal of the European Academy of Dermatology and Venereology
- Vol. 23 (11) , 1246-1253
Abstract
In Russia, laboratory diagnosis of gonorrhoea has been mainly based on microscopy only and, in some settings, relatively rare suboptimal culturing. In recent years, Russian developed and manufactured nucleic acid amplification tests (NAAT) have been implemented for routine diagnosis of Neisseria gonorrhoeae. However, these NAATs have never been validated to any international well-recognized diagnostic NAAT. This study aims to evaluate the performance characteristics of six Russian NAATs for N. gonorrhoeae diagnostics. In total, 496 symptomatic patients were included. Five polymerase chain reaction (PCR) assays and one real-time nucleic acid sequence based amplification (NASBA) assay, developed by three Russian companies, were evaluated on urogenital samples, i.e. cervical and first voided urine (FVU) samples from females (n = 319), urethral and FVU samples from males (n = 127), and extragenital samples, i.e. rectal and pharyngeal samples, from 50 additional female patients with suspicion of gonorrhoea. As reference method, an international strictly validated real-time porA pseudogene PCR was applied. The prevalence of N. gonorrhoeae was 2.7% and 16% among the patients providing urogenital and extragenital samples, respectively. The Russian NAATs and the reference method displayed high level of concordance (99.4-100%). The sensitivities, specificities, positive predictive values and negative predictive values of the Russian tests in different specimens were 66.7-100%, 100%, 100%, and 99.4-100%, respectively. Russian N. gonorrhoeae diagnostic NAATs comprise relatively good performance characteristics. However, larger studies are crucial and, beneficially, the Russian assays should also be evaluated to other international highly sensitive and specific, and ideally Food and Drug Administration approved, NAATs such as Aptima Combo 2 (Gen-Probe).Keywords
This publication has 28 references indexed in Scilit:
- Clinical Validation of a Real-Time Polymerase Chain Reaction Detection of Neisseria gonorrheae porA Pseudogene Versus Culture TechniquesSexually Transmitted Diseases, 2008
- Comparison of microscopy, culture and in‐house PCR and NASBA assays for diagnosis of Neisseria gonorrhoeae in RussiaAPMIS, 2008
- Neisseria gonorrhoeae population in Arkhangelsk, Russia: phenotypic and genotypic heterogeneityClinical Microbiology and Infection, 2007
- A Fast Real-Time Polymerase Chain Reaction Method for Sensitive and Specific Detection of the Neisseria gonorrhoeae porA PseudogeneThe Journal of Molecular Diagnostics, 2006
- Evidence that the gonococcal porA pseudogene is present in a broad range of Neisseria gonorrhoeae strains; suitability as a diagnostic targetPathology, 2006
- Comparison of the Gen-Probe APTIMA Combo 2 Assay to the AMPLICOR CT/NG Assay for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Urine Samples from Australian Men and WomenJournal of Clinical Microbiology, 2006
- Laboratory diagnosis of Neisseria gonorrhoeae in St Petersburg, Russia: inventory, performance characteristics and recommended optimisationsSexually Transmitted Infections, 2006
- Utility of Pooled Urine Specimens for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Men Attending Public Sexually Transmitted Infection Clinics in Mumbai, India, by PCRJournal of Clinical Microbiology, 2005
- A new confirmatory Neisseria gonorrhoeae real-time PCR assay targeting the porA pseudogeneEuropean Journal of Clinical Microbiology & Infectious Diseases, 2004
- Evaluation of the Specificities of Five DNA Amplification Methods for the Detection of Neisseria gonorrhoeaeJournal of Clinical Microbiology, 2003