Evaluation of Hardware-Related Complications in Vascularized Bone Grafts With Locking Mandibular Reconstruction Plate Fixation
Authors:
- Jeffrey D. SuhJSJeffrey D. Suh
- Vishad NabiliVNVishad Nabili
- Joel A. SercarzJSJoel A. Sercarz
- Christian HeadCHChristian Head
- Elliot AbemayorEAElliot Abemayor
- Keith E. BlackwellKBKeith E. Blackwell
- 1 December 2007
- journal article
- research article
- Published by American Medical Association (AMA) in JAMA Otolaryngology–Head & Neck Surgery
- Vol. 133 (12) , 1302-1306
Abstract
Research from JAMA Otolaryngology–Head & Neck Surgery — Evaluation of Hardware-Related Complications in Vascularized Bone Grafts With Locking Mandibular Reconstruction Plate FixationKeywords
This publication has 18 references indexed in Scilit:
- Efficacy of small reconstruction plates in vascularized bone graft mandibular reconstructionHead & Neck, 2006
- Use of the 2.0‐mm Locking Reconstruction Plate in Primary Oromandibular Reconstruction after Composite ResectionOtolaryngology–Head and Neck Surgery, 2004
- Comparison of miniplates and reconstruction plates in mandibular reconstructionHead & Neck, 2003
- Assessment of Plate Use for Mandibular Reconstruction: Has Changing Technology Made a Difference?Otolaryngology–Head and Neck Surgery, 1999
- Reconstruction of the Mandible with Osseous Free Flaps: A 10-Year Experience with 150 Consecutive PatientsPlastic and Reconstructive Surgery, 1999
- The Bridging Lateral Mandibular Reconstruction Plate RevisitedJAMA Otolaryngology–Head & Neck Surgery, 1999
- Rigid Fixation of Vascularized Bone Grafts in Mandibular ReconstructionJAMA Otolaryngology–Head & Neck Surgery, 1995
- Fixation of the Vascularized Bone Graft in Mandibular ReconstructionPlastic and Reconstructive Surgery, 1993
- Experience with AO reconstruction plates after partial mandibular resection involving its continuityJournal of Cranio-Maxillofacial Surgery, 1991
- Titanium Miniplate Fixation in Free Flap Mandible ReconstructionAnnals of Plastic Surgery, 1989