Utility of the surface electrocardiogram for confirming right ventricular septal pacing: validation using electroanatomical mapping
Authors:
Open Access
- 9 September 2010
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 13 (1) , 82-86
Abstract
When targeting the interventricular septum during pacemaker implantation, the lead may inadvertently be positioned on the anterior wall due to imprecise fluoroscopic landmarks. Surface electrocardiogram (ECG) criteria of the paced QRS complex (e.g. negativity in lead I) have been proposed to confirm a septal position, but these criteria have not been properly validated. Our aim was to investigate whether the paced QRS complex may be used to confirm septal lead position. Anatomical reconstruction of the right ventricle was performed using a NavX® system in 31 patients (70 ± 11 years, 26 males) to validate pacing sites. Surface 12-lead ECGs were analysed by digital callipers and compared while pacing from a para-Hissian position, from the mid-septum, and from the anterior free wall. Duration of the QRS complex was not significantly shorter when pacing from the mid-septum compared with the other sites. QRS axis was significantly less vertical during mid-septal pacing (18 ± 51°) compared with para-Hissian (38 ± 37°, P = 0.028) and anterior (53 ± 55°, P = 0.003) pacing, and QRS transition was intermediate (4.8 ± 1.3 vs. 3.8 ± 1.3, P < 0.001, and vs. 5.4 ± 0.9, P = 0.045, respectively), although no cut-offs could reliably distinguish sites. A negative QRS or the presence of a q-wave in lead I tended to be more frequent with anterior than with mid-septal pacing (9/31 vs. 3/31, P = 0.2 and 8/31 vs. 1/31, P = 1.0, respectively). No single ECG criterion could reliably distinguish pacing the mid-septum from the anterior wall. In particular, a negative QRS complex in lead I is an inaccurate criterion for validating septal pacing.Keywords
This publication has 18 references indexed in Scilit:
- Pacing from the Right Ventricular Septum: Is There a Danger to the Coronary Arteries?Pacing and Clinical Electrophysiology, 2009
- Long-Term Impact of Right Ventricular Septal Versus Apical Pacing on Left Ventricular Synchrony and Function in Patients With Second- or Third-Degree Heart BlockThe American Journal of Cardiology, 2009
- Minimizing Ventricular Pacing to Reduce Atrial Fibrillation in Sinus-Node DiseaseNew England Journal of Medicine, 2007
- The Right Ventricular Outflow Tract: The Road to Septal PacingPacing and Clinical Electrophysiology, 2007
- Right Ventricular Outflow Tract Pacing: Radiographic and Electrocardiographic Correlates of Lead PositionPacing and Clinical Electrophysiology, 2006
- Ventricular Pacing Lead Location Alters Systemic Hemodynamics and Left Ventricular Function in Patients With and Without Reduced Ejection FractionJACC, 2006
- Selective Site Pacing:Pacing and Clinical Electrophysiology, 2004
- Adverse Effect of Ventricular Pacing on Heart Failure and Atrial Fibrillation Among Patients With Normal Baseline QRS Duration in a Clinical Trial of Pacemaker Therapy for Sinus Node DysfunctionCirculation, 2003
- The Effect of Ventricular Activation Sequence on Cardiac Performance During PacingPacing and Clinical Electrophysiology, 1996
- Hemodynamic importance of preserving the normal sequence of ventricular activation in permanent cardiac pacingAmerican Heart Journal, 1995