Design configurations analysis of wind-induced natural ventilation tower in hot humid climate using computational fluid dynamics
Open Access
- 19 June 2013
- journal article
- research article
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 10 (4) , 332-346
Abstract
Wind-induced natural ventilation tower is one of the effective devices in enhancing indoor air quality. It can be designed and integrated as part of building components. This paper investigates the performance of various design configurations of a wind-induced natural ventilation tower with the focus on Venturi-shaped roofs and towers. The Venturi-shaped roofs and towers are used to create negative pressure in order to enhance the extraction air flow rates of the wind-induced natural ventilation tower. The computational fluid dynamics (CFD) method is used to analyse each of the design configurations. The different design configurations are based on roof tilt angles, roofs' shapes, tower heights and shapes of the wind-induced natural ventilation tower. The parameters analysed are extraction air flow rates and air flow pattern. Based on the CFD simulation results of various design configurations, the ‘biconcave’-shaped wind tower has the best design configuration with 14 568.66 m3/h extraction air flow rates at 0.8 m/s external wind velocity.Keywords
This publication has 15 references indexed in Scilit:
- A comparison of the thermal adaptability of people accustomed to air-conditioned environments and naturally ventilated environmentsIndoor Air, 2011
- The Improvement of Ventilation Behaviours in Kitchens of Residential BuildingsIndoor and Built Environment, 2011
- A venturi-shaped roof for wind-induced natural ventilation of buildings: Wind tunnel and CFD evaluation of different design configurationsBuilding and Environment, 2011
- Ventilation rates and health: multidisciplinary review of the scientific literatureIndoor Air, 2011
- Short-term airing by natural ventilation - modeling and control strategiesIndoor Air, 2009
- Field Measurement and Subjects' Votes Assessment on Thermal Comfort in High-rise Hostels in MalaysiaIndoor and Built Environment, 2008
- Computational analysis of wind driven natural ventilation in buildingsEnergy and Buildings, 2006
- The influence of the wind-blocking effect by a building on its wind-driven rain exposureJournal of Wind Engineering and Industrial Aerodynamics, 2006
- Using computational tools to factor wind into architectural environment designEnergy and Buildings, 2004
- Comprehensive Approach to Verification and Validation of CFD Simulations—Part 1: Methodology and ProceduresJournal of Fluids Engineering, 2001