The Relationship between Bacterial Load and Initial Run Time of a Surgical Helmet
Open Access
- 1 December 2022
- journal article
- research article
- Published by Elsevier in Journal of Shoulder and Elbow Arthroplasty
- Vol. 6
Abstract
Background: Periprosthetic joint infection (PJI) is a complication of arthroplasty surgery with significant morbidity and mortality. Surgical helmets are a possible source of infection. Pre-existing dust and microorganisms on its surface may be blown into the surgical field by the helmet ventilation system. Methods: Twenty surgical helmets at our institution were assessed through microscopy and polymerase chain reaction testing. Helmets were arranged with agar plates under the front and rear outflow vents. Helmets ran while plates were exchanged at different time points. Bacterial growth was assessed via colony counts and correlated with fan operating time. Gram staining and 16S sequencing were performed to identify bacterial species. Results: The primary microbiological contaminate identified was Burkholderia. There was an inverse relationship between colony formation and fan operating time. The highest number of colonies was found within the first minute of fan operating time. There was a significant decrease in the number of colonies formed from the zero-minute to the three (27 vs 5; P = <.01), four (27 vs 3; P = <.01), and five-minute (27 vs 4; P = <.01) time points for the front outflow plates. A significant difference was also observed between the one-minute and four-minute time points ( P = .046). Conclusion: We observed an inverse relationship between bacterial spread helmet fan operation time, which may correlate with dispersion of pre-existing contaminates. To decrease contamination risk, we recommend that helmets are run for at least 3 min prior to entering the operating room.Keywords
This publication has 18 references indexed in Scilit:
- Minor revision to V4 region SSU rRNA 806R gene primer greatly increases detection of SAR11 bacterioplanktonAquatic Microbial Ecology, 2015
- Prosthetic Joint InfectionClinical Microbiology Reviews, 2014
- Risk factors associated with surgical site infection in 30 491 primary total hip replacementsThe Journal of Bone and Joint Surgery. British volume, 2012
- Does the use of laminar flow and space suits reduce early deep infection after total hip and knee replacement?The Journal of Bone and Joint Surgery. British volume, 2011
- Comparison of antibiotic susceptibility of Burkholderia cepacia complex organisms when grown planktonically or as biofilm in vitroEuropean Journal of Clinical Microbiology & Infectious Diseases, 2007
- Gram StainingCurrent Protocols in Microbiology, 2005
- Bacillus Cereus: A significant pathogen in postoperative and post-traumatic wounds on orthopaedic wardsScandinavian Journal of Infectious Diseases, 1991
- The influence of the total body exhaust suit on air and wound contamination in elective hipoperationsJournal of Hospital Infection, 1983
- Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study.BMJ, 1982
- A sterile-air operating theatre enclosureBritish Journal of Surgery, 1964