Abstract
This practice-based study evaluated the clinical performance and risk factors for biological and technical complications with conventionally luted zirconia crowns. Sixty-eight patients (39 female) with a total of 323 restorations placed on 219 vital teeth, 69 endodontically treated teeth (ETT), and 41 implants (incisors, 96; premolars, 89; molars, 138; observational period, 79.7 ± 14.2 months) underwent a clinical follow-up examination and were included in the study. Time-dependent survival (in situ), success (event free), and veneering ceramic fracture (VCF) rates were calculated and analyzed relative to the following risk factors: smoking status, location of the crown, and type of abutment. Fifty-three complete failures were recorded. A significant influence of the abutment type on survival could be detected (p = 0.033): ETT demonstrated a significantly (p = 0.029) lower 7-year survival rate (73.8 %, 95 % confidence interval [95 % CI] 0.600–0.876) than crowns placed on implants (90.0 %, 95 % CI 0.814–0.990). The success rate of the crowns was significantly influenced by the location of the restoration (p = 0.0058). A total of 75.6 % (95 % CI 0.648–0.864) of the anterior crowns remained event free, compared to 50.4 % (95 % CI 0.388–0.621) of the molar crowns. Furthermore, the location of the crowns affected the VCF rate (p = 0.018, event-free anterior teeth 95.2 % (95 % CI 0.880–1), event-free molars 80.9 % (95 % CI 0.706–0.913)). Survival and success rates were significantly influenced by the type of abutment and the location of the restoration. More complete failures should be expected for crowns placed on ETT, while crowns on molars demonstrated more biological and technical complications than anterior zirconia crowns.Keywords
This publication has 33 references indexed in Scilit:
- Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow‐up of 5 yearsClinical Oral Implants Research, 2012
- A 3‐year prospective study of implant‐supported, single‐tooth restorations of all‐ceramic and metal‐ceramic materials in patients with tooth agenesisClinical Oral Implants Research, 2012
- A 5-year retrospective study of survival of zirconia single crowns fitted in a private clinical settingJournal of Dentistry, 2012
- A retrospective analysis of 102 zirconia single crowns with knife-edge marginsThe Journal of Prosthetic Dentistry, 2012
- Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal–ceramic fixed dental prosthesesDental Materials, 2012
- Failure Time Analysis2009
- Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs)Clinical Oral Investigations, 2009
- Marginal and internal fits of fixed dental prostheses zirconia retainersDental Materials, 2009
- Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial denturesEuropean Journal of Oral Sciences, 2008
- A systematic review of the survival and complication rates of all‐ceramic and metal–ceramic reconstructions after an observation period of at least 3 years. Part I: single crownsClinical Oral Implants Research, 2007