Abstract
An analytical approach to size DC link capacitor for a 3-phase current controlled voltage source inverter used for permanent magnet synchronous motor is presented in this paper considering the DC-link ripple voltage and capacitor ripple current. The analytical method derived in this paper shows the variation of DC link voltage ripple with the change of power factor and modulation index. This analysis can be applied to determine the maximum possible ripple voltage for a given capacitor or the minimum capacitance needed to keep the voltage ripple under a limit. Then current ripple analysis is used to determine the RMS capacitor ripple current taking account of the thermal duty cycles of the application. Finally, capacitor life estimation analysis is used using the operating condition, thermal duty cycle and ripple current to determine capacitor end life for a given application. The research presents a sequential process to select a DC-link capacitor accounting for electrical and thermal requirement of the system. The analysis is verified by simulation and experimental results where the effect of components parasitic on the voltage and current ripple is presented.