Total Knee Arthroplasty as Salvage for Non Union in Bicondylar Hoffa Fracture: a report of two cases
Open Access
- 1 October 2011
- Vol. 1 (1) , 26-28
Abstract
Bicondylar Hoffa fracture is a rare injury with implant failure and non unions as known complications. Two cases of Bicondylar Hoffa fractures with implant failure and nonunion treated successfully with long stem total knee arthroplasty are reported here. At a minimum follow up of 2 years both the implants were well fixed and the fractures have united. The knee society scores in both the patients improved from 14 and 19 to 86 and 82 respectively. To our knowledge there are no reports of such rare fractures managed successfully with non hinged arthroplasty. A long stem total knee arthroplasty can be used as a treatment option in cases of nonunion bicondylar Hoffa fracturesKeywords
This publication has 5 references indexed in Scilit:
- Total Knee Arthroplasty for Salvage of Failed Internal Fixation or Nonunion of the Distal FemurThe Journal of Arthroplasty, 2005
- Cruciate fracture of the distal femur: the double Hoffa fractureInjury, 2004
- Operative Treatment of Unilateral Bicondylar Hoffa FracturesJournal of Orthopaedic Trauma, 2004
- Primary knee arthroplasty for distal femoral fractures in elderly patients.1992
- Treatment of Juxtaarticular Nonunion Fractures at the Knee With Long-Stem Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1990