Location of Reentry Tears Affects False Lumen Thrombosis in Aortic Dissection Following TEVAR
Authors:
Open Access
- 4 May 2020
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 27 (3) , 396-404
Abstract
Purpose: To report a study that assesses the influence of the distance between the distal end of a thoracic stent-graft and the first reentry tear (SG-FRT) on the progression of false lumen (FL) thrombosis in patients who underwent thoracic endovascular aortic repair (TEVAR). Materials and Methods: Three patient-specific geometrical models were reconstructed from postoperative computed tomography scans. Two additional models were created by artificially changing the SG-FRT distance in patients 1 and 2. In all 5 models, computational fluid dynamics simulations coupled with thrombus formation modeling were performed at physiological flow conditions. Predicted FL thrombosis was compared to follow-up scans. Results: There was reduced false lumen flow and low time-averaged wall shear stress (TAWSS) in patients with large SG-FRT distances. Predicted thrombus formation and growth were consistent with follow-up scans for all patients. Reducing the SG-FRT distance by 30 mm in patient 1 increased the flow and time-averaged wall shear stress in the upper abdominal FL, reducing the thrombus volume by 9.6%. Increasing the SG-FRT distance in patient 2 resulted in faster thoracic thrombosis and increased total thrombus volume. Conclusion: The location of reentry tears can influence the progression of FL thrombosis following TEVAR. The more distal the reentry tear in the aorta the more likely it is that FL thrombosis will occur. Hence, the distal landing zone of the stent-graft should be chosen carefully to ensure a sufficient SG-FRT distance.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (DTP studentship)
This publication has 25 references indexed in Scilit:
- Mathematical modeling of thrombus formation in idealized models of aortic dissection: initial findings and potential applicationsJournal of Mathematical Biology, 2016
- Multi-modality image-based computational analysis of haemodynamics in aortic dissectionBiomechanics and Modeling in Mechanobiology, 2015
- Management of acute aortic syndromeNature Reviews Cardiology, 2014
- Aortic Hemodynamics After Thoracic Endovascular Aortic Repair, With Particular Attention to the Bird-Beak ConfigurationJournal of Endovascular Therapy, 2014
- Endovascular Repair of Acute Uncomplicated Aortic Type B Dissection Promotes Aortic Remodelling: 1 Year Results of the ADSORB TrialEuropean Journal of Vascular and Endovascular Surgery, 2014
- Early and late management of type B aortic dissectionHeart, 2014
- Risk factors of incomplete thrombosis in the false lumen after endovascular treatment of extensive acute type B aortic dissectionJournal of Vascular Surgery, 2012
- Randomized Comparison of Strategies for Type B Aortic DissectionCirculation, 2009
- Factors Portending Endoleak Formation After Thoracic Aortic Stent-Graft Repair of Complicated Aortic DissectionCirculation: Cardiovascular Interventions, 2009
- INvestigation of STEnt grafts in patients with type B Aortic Dissection: Design of the INSTEAD trial—a prospective, multicenter, European randomized trialAmerican Heart Journal, 2005