A Vascular Interventional Surgical Robotic System Based on Force-Visual Feedback
Authors:
- 13 August 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (23) , 11081-11089
Abstract
In this paper, based on the previous research of our research team. We proposed a Vascular Interventional Surgical Robotic System based on Force-Visual feedback. In the process of vascular interventional surgery, it is very important to accurately detect the resistance force of surgical catheter, which can improve the safety of operation. Therefore, we developed a force sensor for the vascular interventional surgery robotic system based on the principle of resistance strain gauge bridge circuit. In addition, a complete robotic system with only force feedback is not enough. Therefore, it is necessary to combine the visual feedback interface to complete the operation. Finally, some verification experiments have been completed, including the evaluation experiment of the internal fixture of the force sensor, the calibration experiment of the force sensor, the evaluation experiment of the force sensor, the evaluation experiment of the force feedback, The axial and radial synchronous motion experiment between the master and slave side. Experimental results showed that the feasibility of the force sensor. Vascular Interventional Surgical Robotic System based on Force-Visual feedback has good performance of the force feedback and the synchronous motion between the master and slave side. There is a certain error in the synchronous motion between the master and slave side and the force feedback of the vascular interventional surgery robotic system based on Force-Visual feedback, the error is within the allowable range.Keywords
Funding Information
- National Natural Science Foundation of China (61703305)
- Natural Science Foundation of Tianjin Municipality (18JCZDJC38500)
- Innovative Cooperation Project of Tianjin Scientific and Technological Support (18PTZWHZ00090)
- Tianjin Key Laboratory for Control Theory and Application in Complicated Systems (TJKL-CTACS-201701)
This publication has 16 references indexed in Scilit:
- Demonstration of the Safety and Feasibility of Robotically Assisted Percutaneous Coronary Intervention in Complex Coronary LesionsJACC: Cardiovascular Interventions, 2017
- CathROB: A Highly Compact and Versatile Remote Catheter Navigation SystemApplied Bionics and Biomechanics, 2017
- Feasibility and Safety of Robotic Peripheral Vascular InterventionsJACC: Cardiovascular Interventions, 2016
- Design and characteristics evaluation of a novel teleoperated robotic catheterization system with force feedback for vascular interventional surgeryBiomedical Microdevices, 2016
- Design and performance evaluation of a novel master manipulator for the robot-assist catheter system2016
- Design of a haptic device with grasp and push–pull force feedback for a master–slave surgical robotInternational Journal of Computer Assisted Radiology and Surgery, 2015
- Clinical application of a vascular interventional robot in cerebral angiographyThe International Journal of Medical Robotics and Computer Assisted Surgery, 2015
- Silicon nanowire-based ring-shaped tri-axial force sensor for smart integration on guidewireJournal of Micromechanics and Microengineering, 2014
- Toward In-Vivo Force and Motion Measurement for Vascular SurgeryIEEE Transactions on Instrumentation and Measurement, 2014
- A novel control architecture for physiological tremor compensation in teleoperated systemsThe International Journal of Medical Robotics and Computer Assisted Surgery, 2012