A Wide Energy Range and 4π-View Gamma Camera with Interspaced Position-Sensitive Scintillator Array and Embedded Heavy Metal Bars
Open Access
Abstract
(1) Background: Gamma cameras have wide applications in industry, including nuclear power plant monitoring, emergency response, and homeland security. The desirable properties of a gamma camera include small weight, good resolution, large field of view (FOV), and wide imageable source energy range. Compton cameras can have a 4π FOV but have limited sensitivity at low energy. Coded-aperture gamma cameras are operatable at a wide photon energy range but typically have a limited FOV and increased weight due to the thick heavy metal collimators and shielding. In our lab, we previously proposed a 4π-view gamma imaging approach with a 3D position-sensitive detector, with which each detector element acts as the collimator for other detector elements. We presented promising imaging performance for 99mTc, 18F, and 137Cs sources. However, the imaging performance for middle- and high-energy sources requires further improvement. (2) Methods: In this study, we present a new gamma camera design to achieve satisfactory imaging performance in a wide gamma energy range. The proposed gamma camera consists of interspaced bar-shaped GAGG (Ce) crystals and tungsten absorbers. The metal bars enhance collimation for high-energy gamma photons without sacrificing the FOV. We assembled a gamma camera prototype and conducted experiments to evaluate the gamma camera’s performance for imaging 57Co, 137Cs, and 60Co point sources. (3) Results: Results show that the proposed gamma camera achieves a positioning accuracy of 137Cs point sources with 10° separation, two 57Co and two 60Co point sources with 20° separation, as well as a 2 × 3 137Cs point-source array with 20° separation. (4) Conclusions: We conclude that the proposed gamma camera design has comprehensive merits, including portability, 4π-view FOV, and good angular resolution across a wide energy range. The presented approach has promising potential in nuclear security applications.Keywords
Funding Information
- Natural Science Foundation of Beijing Municipality (Z220010, 81727807)
- Tsinghua Precision Medicine Foundation (Z220010, 81727807)
- Tsinghua University Initiative Scientific Research Program (Z220010, 81727807)
- National Natural Science Foundation of China (Z220010, 81727807)
This publication has 30 references indexed in Scilit:
- Development of a 64-Channel Readout ASIC for an SSPM Array for PET and TOF-PET ApplicationsIEEE Transactions on Nuclear Science, 2016
- Energy Resolution and Temperature Dependence of Ce:GAGG Coupled to Silicon PhotomultipliersIEEE Transactions on Nuclear Science, 2016
- Choice of crystal surface finishing for a dual-ended readout depth-of-interaction (DOI) detectorPhysics in Medicine & Biology, 2016
- A prototype of aerial radiation monitoring system using an unmanned helicopter mounting a GAGG scintillator Compton cameraJournal of Nuclear Science and Technology, 2015
- The Polaris-H imaging spectrometerNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Compact hybrid gamma camera with a coded aperture for investigation of nuclear materialsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Depth of interaction calibration for PET detectors with dual-ended readout by PSAPDsPhysics in Medicine & Biology, 2008
- A gamma-ray imager for arms controlIEEE Transactions on Nuclear Science, 1992
- A proposed γ cameraNature, 1974
- Use of a Gamma-Ray Pinhole Camera for in vivo StudiesNature, 1952