Comparison of prostate set‐up accuracy and margins with off‐line bony anatomy corrections and online implanted fiducial‐based corrections
Authors:
- K DahlKDK Dahl
- Ma EbertMEMa Ebert
- C WrattenCWC Wratten
- M WhiteMWM White
- Jw DenhamJDJw Denham
- 30 October 2008
- journal article
- research article
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 52 (5) , 511-516
Abstract
The aim of the study was to determine prostate set-up accuracy and set-up margins with off-line bony anatomy-based imaging protocols, compared with online implanted fiducial marker-based imaging with daily corrections. Eleven patients were treated with implanted prostate fiducial markers and online set-up corrections. Pretreatment orthogonal electronic portal images were acquired to determine couch shifts and verification images were acquired during treatment to measure residual set-up error. The prostate set-up errors that would result from skin marker set-up, off-line bony anatomy-based protocols and online fiducial marker-based corrections were determined. Set-up margins were calculated for each set-up technique using the percentage of encompassed isocentres and a margin recipe. The prostate systematic set-up errors in the medial–lateral, superior–inferior and anterior–posterior directions for skin marker set-up were 2.2, 3.6 and 4.5 mm (1 standard deviation). For our bony anatomy-based off-line protocol the prostate systematic set-up errors were 1.6, 2.5 and 4.4 mm. For the online fiducial based set-up the results were 0.5, 1.4 and 1.4 mm. A prostate systematic error of 10.2 mm was uncorrected by the off-line bone protocol in one patient. Set-up margins calculated to encompass 98% of prostate set-up shifts were 11–14 mm with bone off-line set-up and 4–7 mm with online fiducial markers. Margins from the van Herk margin recipe were generally 1–2 mm smaller. Bony anatomy-based set-up protocols improve the group prostate set-up error compared with skin marks; however, large prostate systematic errors can remain undetected or systematic errors increased for individual patients. The margin required for set-up errors was found to be 10–15 mm unless implanted fiducial markers are available for treatment guidanceKeywords
This publication has 12 references indexed in Scilit:
- X-ray–assisted positioning of patients treated by conformal arc radiotherapy for prostate cancer: Comparison of setup accuracy using implanted markers versus bony structuresInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Comparison of daily megavoltage electronic portal imaging or kilovoltage imaging with marker seeds to ultrasound imaging or skin marks for prostate localization and treatment positioning in patients with prostate cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imagingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Application of the No Action Level (NAL) protocol to correct for prostate motion based on electronic portal imaging of implanted markersInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinomaInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- Inclusion of geometric uncertainties in treatment plan evaluationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2002
- Daily prostate targeting using implanted radiopaque markersInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2002
- Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markersRadiotherapy and Oncology, 2001
- A verification procedure to improve patient set-up accuracy using portal imagesRadiotherapy and Oncology, 1993
- Objective decision-making following a portal film: The results of a pilot studyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1993