Late infections after dynamic stabilization of the lumbar spine with Dynesys
- 19 May 2012
- journal article
- Published by Springer Nature in European Spine Journal
- Vol. 21 (12) , 2573-2579
Abstract
Dynamic stabilization of the spine was developed as an alternative to rigid fusion in chronic back pain to reduce the risk of adjacent segment degeneration. Dynamic neutralization system (Dynesys, Zimmer CH) is one of the most popular systems available, but some midterm studies show revision rates as high as 30 %. Some late infectious complications in our patients prompted us to review them systematically. Propionibacterium recently has been shown to cause subtle infections of prosthetic material. Here, we report on a consecutive series of 50 Dynesys implants. In a median follow-up of 51 months (range 0–91), we identified 12 infectious and 11 non-infectious complications necessitating reoperation or removal of the implant in 17 patients. Material infections occurred after a median of 52 months (2–77) and were due to Propionibacterium alone (n = 4) or in combination (n = 3) in seven out of 11 patients. Clinical presentation combines new or increasing pain associated with signs of screw loosening on conventional X-rays; however, as many as 73.5 % of patients present some degree of screw loosening without being at all symptomatic of infection. The high rate of late infections with low-grade germs and the frequency of screw loosening signs made us suspect a lack of integration at the bone-screw interface. Surgeons should be suspicious if the patient presents a combination of new or increasing pain and signs of screw loosening, and aggressive revision is recommended in these cases.Keywords
This publication has 22 references indexed in Scilit:
- Dynamic stabilization adjacent to single-level fusion: Part I. Biomechanical effects on lumbar spinal motionEuropean Spine Journal, 2010
- Dynamic stabilization adjacent to single-level fusion: Part II. No clinical benefit for asymptomatic, initially degenerated adjacent segments after 6 years follow-upEuropean Spine Journal, 2010
- Posterior dynamic stabilization of the lumbar spine with the Accuflex rod system as a stand-alone device: experience in 20 patients with 2-year follow-upEuropean Spine Journal, 2010
- Risk factors for deep surgical site infections after spinal fusionEuropean Spine Journal, 2010
- Segment-by-segment stabilization for degenerative disc disease: a hybrid techniqueEuropean Spine Journal, 2010
- Inter-observer reliability of detecting Dynesys pedicle screw using plain X-rays: a study on 50 post-operative patientsEuropean Spine Journal, 2009
- Risk factors for adjacent segment disease after lumbar fusionEuropean Spine Journal, 2009
- Clinical and radiological outcome of anterior–posterior fusion versus transforaminal lumbar interbody fusion for symptomatic disc degeneration: a retrospective comparative study of 133 patientsEuropean Spine Journal, 2009
- The myth of lumbar instability: the importance of abnormal loading as a cause of low back painEuropean Spine Journal, 2008
- The diagnosis and management of infection following instrumented spinal fusionEuropean Spine Journal, 2007