Dual signal subspace projection (DSSP): a novel algorithm for removing large interference in biomagnetic measurements
- 11 April 2016
- journal article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 13 (3) , 036007
Abstract
Objective. In functional electrophysiological imaging, signals are often contaminated by interference that can be of considerable magnitude compared to the signals of interest. This paper proposes a novel algorithm for removing such interferences that does not require separate noise measurements. Approach. The algorithm is based on a dual definition of the signal subspace in the spatial- and time-domains. Since the algorithm makes use of this duality, it is named the dual signal subspace projection (DSSP). The DSSP algorithm first projects the columns of the measured data matrix onto the inside and outside of the spatial-domain signal subspace, creating a set of two preprocessed data matrices. The intersection of the row spans of these two matrices is estimated as the time-domain interference subspace. The original data matrix is projected onto the subspace that is orthogonal to this interference subspace. Main results. The DSSP algorithm is validated by using the computer simulation, and using two sets of real biomagnetic data: spinal cord evoked field data measured from a healthy volunteer and magnetoencephalography data from a patient with a vagus nerve stimulator. Significance. The proposed DSSP algorithm is effective for removing overlapped interference in a wide variety of biomagnetic measurements.Keywords
This publication has 22 references indexed in Scilit:
- Magnetospinography: Instruments and Application to Functional Imaging of Spinal CordsIEICE Transactions on Electronics, 2013
- A probabilistic algorithm for robust interference suppression in bioelectromagnetic sensor dataStatistics in Medicine, 2007
- A graphical model for estimating stimulus-evoked brain responses from magnetoencephalography data with large background brain activityNeuroImage, 2006
- Spatiotemporal signal space separation method for rejecting nearby interference in MEG measurementsPhysics in Medicine & Biology, 2006
- Visualization of incomplete conduction block by neuromagnetic recordingClinical Neurophysiology, 2004
- Three dimensionally configured SQUID vector gradiometers for biomagnetic measurementSuperconductor Science and Technology, 2003
- Signal-space projection method for separating MEG or EEG into componentsMedical & Biological Engineering & Computing, 1997
- Interpreting magnetic fields of the brain: minimum norm estimatesMedical & Biological Engineering & Computing, 1994
- Electrophysiologic Diagnosis of Cervical OPLL Myelopathy Using Evoked Spinal Cord PotentialsSpine, 1988
- Basic mathematical and electromagnetic concepts of the biomagnetic inverse problemPhysics in Medicine & Biology, 1987