Rigid piston approximation for computing the transfer function and angular response of a fiber-optic hydrophone
Authors:
- 1 April 2000
- journal article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 107 (4) , 1994-2003
Abstract
The transfer function of a fiber-optic hydrophone (FOH) is computed for various fiber core radii. The hydrophone is modeled as a rigid disk, with plane waves impinging at normal or oblique incidence. The total sound field is written as the sum of the incident field and the field diffracted from the hydrophone. The diffracted field is approximated by the field generated by a vibrating planar piston in an infinite rigid baffle. For normal incidence and a pointlike fiber core, an analytical solution is presented. For finite fiber core radii, and for oblique incidence, the transfer functions are computed numerically. The calculated transfer functions exhibit an oscillatory frequency dependency that is most pronounced for small fiber cores. The solution for a core radius of 2.5 μm can be very well approximated by the analytical solution for a pointlike core at frequencies of up to 30 MHz. The results for normal incidence can be directly employed to deconvolute ultrasonic pressure signals measured with an FOH. From the transfer functions for oblique incidence, the angular response of the hydrophone is calculated. The angular response obtained here differs significantly from the model commonly used for piezoelectric hydrophones. The effective hydrophone radius derived from the angular response shows a strong frequency dependency. For low frequencies, it is found to be larger than the outer fiber radius, whereas it generally lies between the outer radius and the fiber core radius for frequencies above 10 MHz.Keywords
This publication has 14 references indexed in Scilit:
- Coated fiber-optic hydrophone for ultrasonic measurementUltrasonics, 1996
- High-frequency membrane hydrophoneIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1996
- Fibre-optic probe hydrophone for ultrasonic and shock-wave measurements in waterUltrasonics, 1993
- Use of Miniature Hydrophones to Determine Peak Intensities Typical of Medical Ultrasound DevicesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1986
- Characteristics of a PVDF Membrane Hydrophone for Use in the Range 1-100 MHzIEEE Transactions on Sonics and Ultrasonics, 1982
- Miniature piezoelectric polymer ultrasonic hydrophone probesUltrasonics, 1981
- Review of transient field theory for a baffled planar pistonThe Journal of the Acoustical Society of America, 1981
- Transient field of a baffled planar piston having an arbitrary vibration amplitude distributionThe Journal of the Acoustical Society of America, 1981
- Measurement of refractive index of water under high dynamic pressuresJournal of Applied Physics, 1973
- Piezo-Optic Coefficients of LiquidsThe Journal of the Acoustical Society of America, 1967