Validation of the contralateral side as reference for selecting radial head implant sizes
Open Access
- 21 January 2016
- journal article
- research article
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 38 (7) , 801-807
Abstract
Purpose In arthroplasty of comminuted radial head fractures, the contralateral radial head diameter can be used as reference for implant selection. However, potential bilateral asymmetry may result in a mismatch of the implant with the native bone. Therefore, our purpose was to evaluate anatomical right-to-left differences of radial head diameters. We also compared conventional two-dimensional (2D) with three-dimensional (3D) measurements. Methods We used bilateral CT-scans from 25 intact proximal radius pairs of right-handed adult subjects to obtain 50 3D radial head models. After contralateral matching, diameters were calculated using a 3D-based method using an automated circle-fit in standardized cross-sections at the widest level midway through the radial head. The 3D-based diameters were compared to orthogonal line measurements in standard axial CT-slices. Results Three-dimensional analysis yielded a radial head diameter of 23.0 ± 1.7 mm. The dominant right side was significantly wider, with right-to-left differences of 0.2 ± 0.4 mm, with a maximum of 0.9 mm. The 2D-based diameter was 22.9 ± 1.7 mm, which was 0.1 ± 0.3 mm smaller compared to corresponding 3D-based diameter. Conclusions In healthy radial heads, the diameter was biased to the dominant right side, but individual differences were not larger than 1 mm. Compared to implant designs, in which diameter increments are usually 2 mm, this right-bias is not clinically relevant, as it would not affect implant selection. Therefore, the contralateral side can be considered a suitable reference. In clinical practice, the surgeon could estimate this diameter using standard axial CT slices, since its difference with the 3D-based evaluation was also relatively small compared to implant sizing increments.Keywords
Funding Information
- Academisch Medisch Centrum (NL)
This publication has 24 references indexed in Scilit:
- Do the radial head prosthesis components fit with the anatomical structures of the proximal radioulnar joint?Surgical and Radiologic Anatomy, 2014
- Estimation of Base of Middle Phalanx Size Using Anatomical LandmarksThe Journal of Hand Surgery, 2014
- Measurements of the ispilateral capitellum can reliably predict the diameter of the radial headJournal of Shoulder and Elbow Surgery, 2013
- Three-Dimensional Assessment of Bilateral Symmetry of the Radius and Ulna for Planning Corrective SurgeriesThe Journal of Hand Surgery, 2012
- Computer-Assisted Planning and Navigation for Corrective Distal Radius Osteotomy, Based on Pre- and Intraoperative ImagingIEEE Transactions on Biomedical Engineering, 2010
- Quantitative three-dimensional computed tomography measurement of radial head fracturesJournal of Shoulder and Elbow Surgery, 2010
- Computed tomography study of radial head morphologyJournal of Shoulder and Elbow Surgery, 2008
- Reference Points for Radial Head Prosthesis SizeThe Journal of Hand Surgery, 2006
- The Effect of Radial Head Excision and Arthroplasty on Elbow Kinematics and StabilityJournal of Bone and Joint Surgery, 2004
- Biomechanical and computer analysis of radial head prosthesesJournal of Shoulder and Elbow Surgery, 1997