Ozone sonde cell current measurements and implications for observations of near-zero ozone concentrations in the tropical upper troposphere
Authors:
Open Access
- 29 April 2010
- journal article
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 3 (2) , 495-505
Abstract
Laboratory measurements of the Electrochemical Concentration Cell (ECC) ozone sonde cell current using ozone free air as well as defined amounts of ozone reveal that background current measurements during sonde preparation are neither constant as a function of time, nor constant as a function of ozone concentration. Using a background current, measured at a defined timed after exposure to high ozone may often overestimate the real background, leading to artificially low ozone concentrations in the upper tropical troposphere, and may frequently lead to operator dependent uncertainties. Based on these laboratory measurements an improved cell current to partial pressure conversion is proposed, which removes operator dependent variability in the background reading and possible artifacts in this measurement. Data from the Central Equatorial Pacific Experiment (CEPEX) have been reprocessed using the improved background treatment based on these laboratory measurements. In the reprocessed data set near-zero ozone events no longer occur. At Samoa, Fiji, Tahiti, and San Cristóbal, nearly all near-zero ozone concentrations occur in soundings with larger background currents. To a large extent, these events are no longer observed in the reprocessed data set using the improved background treatment.Keywords
All Related Versions
This publication has 16 references indexed in Scilit:
- On the distribution and variability of ozone in the tropical upper troposphere: Implications for tropical deep convection and chemical‐dynamical couplingGeophysical Research Letters, 2005
- Southern Hemisphere Additional Ozonesondes (SHADOZ) 1998–2000 tropical ozone climatology 1. Comparison with Total Ozone Mapping Spectrometer (TOMS) and ground‐based measurementsJournal of Geophysical Research: Atmospheres, 2003
- Electrochemical concentration cell (ECC) ozonesonde pump efficiency measurements and tests on the sensitivity to ozone of buffered and unbuffered ECC sensor cathode solutionsJournal of Geophysical Research: Atmospheres, 2002
- Climatology of intrusions into the tropical upper troposphereGeophysical Research Letters, 2000
- Stratosphere‐troposphere exchange of ozone associated with the equatorial Kelvin wave as observed with ozonesondes and rawinsondesJournal of Geophysical Research: Atmospheres, 1998
- Observations of Near-Zero Ozone Concentrations Over the Convective Pacific: Effects on Air ChemistryScience, 1996
- Accuracy of ozonesonde measurements in the troposphereJournal of Atmospheric Chemistry, 1996
- Electrochemical concentration cell ozonesonde performance evaluation during STOIC 1989Journal of Geophysical Research: Atmospheres, 1995
- Record low ozone at the South Pole in the spring of 1993Geophysical Research Letters, 1994
- Effects of solution mass transport on the ECC ozonesonde background currentGeophysical Research Letters, 1983