Performance of Fetal Cardiac Volume Derived from VOCAL (Virtual Organ Computer-Aided AnaLysis) in Predicting Hemoglobin (Hb) Bart’s Disease
Open Access
- 11 October 2021
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (20) , 4651
Abstract
Objective: To determine the performance of fetal cardiac volume (CV) in the detection of fetal Hb Bart’s disease among fetuses at risk at 18–22 weeks of gestation and to compare the performance with those of cardiothoracic diameter ratio (CTR) and middle cerebral artery peak systolic velocity (MCA-PSV). Methods: Fetuses at risk of Hb Bart’s disease between 18 and 22 weeks of gestation prospectively underwent echocardiography with acquisition of the volume datasets (VDS) of fetal heart, using 4D-cardiac STIC. Subsequently, off-line analysis was blindly performed to measure cardiac volume using the VOCAL technique. Results: A total of 502 fetuses at risk meeting the inclusion criteria were included in the analysis, consisting of 117 (23.3%) fetuses with Hb Bart’s disease and 385 (76.7%) unaffected fetuses. The mean (±SD) gestational age at the time of ultrasound examination was 19.70 ± 1.3 weeks. In predicting fetal Hb Bart’s disease, CV, using a cut-off Z-score of 1.7, had a sensitivity of 94.9% and specificity of 94.0%. The performance of CV was slightly better than that of CTR but very superior to that of MCA-PSV (areas under curve: 0.988, 0.974 and 0.862, respectively). Conclusions: Fetal CV has a very high performance in predicting fetal Hb Bart’s disease at mid-pregnancy, comparable with CTR and much better than MCA-PSV.Keywords
Funding Information
- The Thailand Research Fund (DPG-6280003)
- Chiang Mai University Research Fund (CMU-2564)
This publication has 14 references indexed in Scilit:
- Sonographic Markers of Fetal α‐Thalassemia MajorJournal of Ultrasound in Medicine, 2015
- Effectiveness of the model for prenatal control of severe thalassemiaPrenatal Diagnosis, 2013
- Ultrasonographic prediction of homozygous α0‐thalassemia using placental thickness, fetal cardiothoracic ratio and middle cerebral artery Doppler: alone or in combination?Ultrasound in Obstetrics & Gynecology, 2010
- Identification of fetuses with hemoglobin Bart's disease using middle cerebral artery peak systolic velocityUltrasound in Obstetrics & Gynecology, 2009
- Sonographic Markers of Hemoglobin Bart Disease at MidpregnancyJournal of Ultrasound in Medicine, 2004
- Noninvasive Diagnosis by Doppler Ultrasonography of Fetal Anemia Due to Maternal Red-Cell AlloimmunizationThe New England journal of medicine, 2000
- Fetal sonographic cardiothoracic ratio at midpregnancy as a predictor of Hb Bart disease.Journal of Ultrasound in Medicine, 1999
- Prevalence of α-thalassemias in northern ThailandHuman Genetics, 1996
- Molecular characterization of severe α‐Thalassemias causing hydrops fetalis in TaiwanAmerican Journal of Medical Genetics, 1991
- Hydrops fetalis associated with Bart's hemoglobin in northern ThailandThe Journal of Pediatrics, 1968