Accelerating 3D‐T1ρ mapping of cartilage using compressed sensing with different sparse and low rank models
- 25 February 2018
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (4) , 1475-1491
Abstract
Purpose: To evaluate the feasibility of using compressed sensing (CS) to accelerate 3D‐T1ρ mapping of cartilage and to reduce total scan times without degrading the estimation of T1ρ relaxation times.Methods: Fully sampled 3D‐T1ρ datasets were retrospectively undersampled by factors 2‐10. CS reconstruction using 12 different sparsifying transforms were compared, including finite differences, temporal and spatial wavelets, learned transforms using principal component analysis (PCA) and K‐means singular value decomposition (K‐SVD), explicit exponential models, low rank and low rank plus sparse models. Spatial filtering prior to T1ρ parameter estimation was also tested. Synthetic phantom (n = 6) and in vivo human knee cartilage datasets (n = 7) were included.Results: Most CS methods performed satisfactorily for an acceleration factor (AF) of 2, with relative T1ρ error lower than 4.5%. Some sparsifying transforms, such as spatiotemporal finite difference (STFD), exponential dictionaries (EXP) and low rank combined with spatial finite difference (L+S SFD) significantly improved this performance, reaching average relative T1ρ error below 6.5% on T1ρ relaxation times with AF up to 10, when spatial filtering was used before T1ρ fitting, at the expense of smoothing the T1ρ maps. The STFD achieved 5.1% error at AF = 10 with spatial filtering prior to T1ρ fitting.Conclusion: Accelerating 3D‐T1ρ mapping of cartilage with CS is feasible up to AF of 10 when using STFD, EXP or L+S SFD regularizers. These three best CS methods performed satisfactorily on synthetic phantom and in vivo knee cartilage for AFs up to 10, with T1ρ error of 6.5%.Keywords
Funding Information
- NIH (R01‐AR060238, R01‐AR067156, R01‐AR068966)
- NIBIB (NIH P41‐EB017183)
This publication has 55 references indexed in Scilit:
- T2 mapping from highly undersampled data by reconstruction of principal component coefficient maps using compressed sensingMagnetic Resonance in Medicine, 2011
- T1ρ MRI in Alzheimer's Disease: Detection of Pathological Changes in Medial Temporal LobeJournal of Neuroimaging, 2011
- Combination of compressed sensing and parallel imaging for highly accelerated first‐pass cardiac perfusion MRIMagnetic Resonance in Medicine, 2010
- Multicomponent T2 relaxation analysis in cartilageMagnetic Resonance in Medicine, 2009
- In vivo T1ρ and T2 mapping of articular cartilage in osteoarthritis of the knee using 3 T MRIOsteoarthritis and Cartilage, 2007
- Improvedk–tBLAST andk–tSENSE using FOCUSSPhysics in Medicine & Biology, 2007
- Sodium and T1ρ MRI for molecular and diagnostic imaging of articular cartilageNMR in Biomedicine, 2006
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Quantitative interpretation of NMR relaxation dataJournal of Magnetic Resonance (1969), 1989