Wavefront analysis and modulation transfer function of three multifocal intraocular lenses
Open Access
- 1 January 2010
- journal article
- research article
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 58 (2) , 109-13
Abstract
Purpose: To evaluate wavefront performance and modulation transfer function (MTF) in the human eye after the implantation of diffractive or refractive multifocal intraocular lenses (IOLs). Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA) were measured in 60 patients after bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon), 40 eyes received the refractive ReZoom (Advanced Medical Optics) and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics). The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA), followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group ( P < 0.001), but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group ( P = 0.007). Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil ( P < 0.001 at all spatial frequencies). Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom.Keywords
This publication has 35 references indexed in Scilit:
- Maximizing Satisfaction with Presbyopia-Correcting Intraocular Lenses: The Missing LinksAmerican Journal of Ophthalmology, 2008
- Prospective functional and clinical comparison of bilateral ReZoom and ReSTOR intraocular lenses in patients 70 years or youngerJournal of Cataract & Refractive Surgery, 2008
- Optical performance of monofocal and multifocal intraocular lenses in the human eyeJournal of Cataract & Refractive Surgery, 2008
- Image quality with multifocal intraocular lenses and the effect of pupil sizeJournal of Cataract & Refractive Surgery, 2007
- Functional vision with bilateral ReZoom and ReSTOR intraocular lenses 6 months after cataract surgeryJournal of Cataract & Refractive Surgery, 2007
- Visual performance and biocompatibility of 2 multifocal diffractive IOLsJournal of Cataract & Refractive Surgery, 2007
- History and development of the apodized diffractive intraocular lensJournal of Cataract & Refractive Surgery, 2006
- Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitroJournal of Cataract & Refractive Surgery, 2005
- Improved functional vision with a modified prolate intraocular lensJournal of Cataract & Refractive Surgery, 2004
- Cataract extraction with multifocal intraocular lens implantationOphthalmology, 2000