A Non-Linear Model for Sensing Moisture Content in Transformers at Reduced Time
- 4 March 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (12) , 4639-4646
Abstract
Moisture content in transformer is a prime indicator of its insulation condition. Presence of moisture accelerates the aging of cellulosic paper insulation thereby reducing the dielectric as well as the mechanical strength of the insulation. In conventional method for sensing moisture content in transformers, sinusoidal excitation is generally applied on the oil-paper insulation system for two cycles from 0.1mHz to 1kHz. However, application of sinusoidal excitations at discrete measurement frequencies leads to long measurement time during low frequency measurement (0.1mHz to 1Hz), which is a practical problem. Besides, as the moisture content increases, the transformer insulation no longer behaves as a linear time invariant system. Therefore, non-linear modeling of insulation is necessary for accurate moisture sensing in transformers. Considering these two facts, in this study a non-linear Wiener model of transformer insulation using sine sweep excitation is proposed for reliable sensing of moisture content at as reduced measurement time. It was observed that the proposed non-linear Wiener model has better moisture sensing capability thereby providing more accurate information regarding the insulation condition in comparison with linear model. Moreover, an appreciable reduction in the total measurement duration was observed, enabling transformer diagnosis to be conducted quickly compared to conventional method.Keywords
Funding Information
- FIST Program (SR/FST/ETI-362/2014)
- DST Government of India SERB Scheme through the Government of India (EEQ/2016/00046)
This publication has 19 references indexed in Scilit:
- Non-linear modeling of oil-paper insulation for condition assessment using non-sinusoidal excitationIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Non-linear effects in dielectric response measurments on oil paper insulated power transformers2015
- An advanced technique for frequency domain spectroscopy of oil-paper insulation at reduced time using triangular excitation2015
- Accelerating Dielectric Response Measurements on Power Transformers—Part II: A Regression ApproachIEEE Transactions on Power Delivery, 2014
- Analysis of dielectric response measurements for condition assessment of oil-paper transformer insulationIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- Basics of broadband impedance spectroscopy measurements using periodic excitationsMeasurement Science and Technology, 2012
- Frequency Response of Oil Impregnated Pressboard and Paper Samples for Estimating Moisture in Transformer InsulationIEEE Transactions on Power Delivery, 2006
- Applications of dielectric spectroscopy in time and frequency domain for HV power equipmentIEEE Electrical Insulation Magazine, 2003
- Review of modern diagnostic techniques for assessing insulation condition in aged transformersIEEE Transactions on Dielectrics and Electrical Insulation, 2003
- Degradation of cellulosic insulationin power transformers.Part 3: Effects of oxygen and water on ageing in oilIEE Proceedings - Science, Measurement and Technology, 2000