Modeling and experimental verification of on-line PD detection in MV covered-conductor overhead networks
Authors:
- 17 February 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 17 (1) , 167-180
Abstract
The falling trees on covered-conductor (CC) overhead distribution lines produce partial discharges (PDs). The measurements have been taken in the laboratory and PD signal characteristics under various circumstances have been described. In this paper, an on-line single-phase PD monitoring system using Rogowski coil is simulated in EMTP-ATP. The simulation results are compared with those obtained from the laboratory measurements. The proposed model can be used to estimate the length of the practical CC lines at which PDs due to falling trees can be detected and localized; thus, deciding the number and positioning of the sensors over a particular length of the CC lines. The different noise sources have been described that cause interference with low level PD signals, which is a major challenge for on-line/on-site condition monitoring. The design aspects of the wireless sensor for this specific application are also discussed. Automatic detection of falling trees will reduce visual inspection work after storms and it will improve reliability and safety of the CC distribution system.Keywords
This publication has 22 references indexed in Scilit:
- On-line PD measuring system modeling and experimental verification for covered-conductor overhead distribution lines2007
- An improved methodology for application of wavelet transform to partial discharge measurement denoisingIEEE Transactions on Dielectrics and Electrical Insulation, 2005
- Implementation of a Rogowski coil for the measurement of partial dischargesReview of Scientific Instruments, 2005
- Wavelet-based denoising of partial discharge signals buried in excessive noise and interferenceIEEE Transactions on Dielectrics and Electrical Insulation, 2003
- Interpretation of wavelet analysis and its application in partial discharge detectionIEEE Transactions on Dielectrics and Electrical Insulation, 2002
- Practical experiences of on-line partial discharge measurements on a variety of medium-voltage electrical equipmentIEEE Transactions on Industry Applications, 1999
- Rogowski coils suit relay protection and measurement ~of power systems\IEEE Computer Applications in Power, 1997
- GIS monitoring sensors1997
- Using Rogowski coils for transient current measurementsEngineering Science & Education Journal, 1993
- Evaluation of digital filters for rejecting discrete spectral interference in on-site PD measurementsIEEE Transactions on Electrical Insulation, 1993