Software performance in segmenting ground-glass and solid components of subsolid nodules in pulmonary adenocarcinomas
- 5 April 2016
- journal article
- chest
- Published by Springer Nature in European Radiology
- Vol. 26 (12) , 4465-4474
Abstract
Objective To evaluate the performance of software in segmenting ground-glass and solid components of subsolid nodules in pulmonary adenocarcinomas. Method Seventy-three pulmonary adenocarcinomas manifesting as subsolid nodules were included. Two radiologists measured the maximal axial diameter of the ground-glass components on lung windows and that of the solid components on lung and mediastinal windows. Nodules were segmented using software by applying five (-850 HU to -650 HU) and nine (-130 HU to -500 HU) attenuation thresholds. We compared the manual and software measurements of ground-glass and solid components with pathology measurements of tumour and invasive components. Results Segmentation of ground-glass components at a threshold of -750 HU yielded mean differences of +0.06 mm (p = 0.83, 95 % limits of agreement, 4.51 to 4.67) and -2.32 mm (p < 0.001, -8.27 to 3.63) when compared with pathology and manual measurements, respectively. For solid components, mean differences between the software (at -350 HU) and pathology measurements and between the manual (lung and mediastinal windows) and pathology measurements were -0.12 mm (p = 0.74, -5.73 to 5.55]), 0.15 mm (p = 0.73, -6.92 to 7.22), and -1.14 mm (p < 0.001, -7.93 to 5.64), respectively. Conclusion Software segmentation of ground-glass and solid components in subsolid nodules showed no significant difference with pathology. Key Points • Software can effectively segment ground-glass and solid components in subsolid nodules. • Software measurements show no significant difference with pathology measurements. • Manual measurements are more accurate on lung windows than on mediastinal windows.Keywords
Funding Information
- The National R&D Program for Cancer Control, Ministry for Health and Welfare, Republic of Korea (1520230)
This publication has 20 references indexed in Scilit:
- Reproducibility of histopathological subtypes and invasion in pulmonary adenocarcinoma. An international interobserver studyLaboratory Investigation, 2012
- Measurement of Focal Ground-glass Opacity Diameters on CT ImagesAcademic Radiology, 2012
- Ground-Glass Nodules on Chest CT as Imaging Biomarkers in the Management of Lung AdenocarcinomaAmerican Journal of Roentgenology, 2011
- International Association for the Study of Lung Cancer/American Thoracic Society/European Respiratory Society International Multidisciplinary Classification of Lung AdenocarcinomaJournal of Thoracic Oncology, 2011
- A Computer-Aided Diagnosis for Evaluating Lung Nodules on Chest CT: the Current Status and PerspectiveKorean Journal of Radiology, 2011
- Volume-Doubling Time of Pulmonary Nodules with Ground Glass Opacity at Multidetector CTAcademic Radiology, 2011
- Persistent Pure Ground-Glass Nodules in the Lung: Interscan Variability of Semiautomated Volume and Attenuation MeasurementsAmerican Journal of Roentgenology, 2010
- Computer-Aided Volumetry of Pulmonary Nodules Exhibiting Ground-Glass Opacity at MDCTAmerican Journal of Roentgenology, 2010
- A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: What is the minimum increase in size to detect growth in repeated CT examinationsEuropean Radiology, 2008
- Inherent Variability of CT Lung Nodule Measurements In Vivo Using Semiautomated Volumetric MeasurementsAmerican Journal of Roentgenology, 2006