PreQual: An automated pipeline for integrated preprocessing and quality assurance of diffusion weighted MRI images
- 3 February 2021
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (1) , 456-470
Abstract
Purpose: Diffusion weighted MRI imaging (DWI) is often subject to low signal‐to‐noise ratios (SNRs) and artifacts. Recent work has produced software tools that can correct individual problems, but these tools have not been combined with each other and with quality assurance (QA). A single integrated pipeline is proposed to perform DWI preprocessing with a spectrum of tools and produce an intuitive QA document.Methods: The proposed pipeline, built around the FSL, MRTrix3, and ANTs software packages, performs DWI denoising; inter‐scan intensity normalization; susceptibility‐, eddy current‐, and motion‐induced artifact correction; and slice‐wise signal drop‐out imputation. To perform QA on the raw and preprocessed data and each preprocessing operation, the pipeline documents qualitative visualizations, quantitative plots, gradient verifications, and tensor goodness‐of‐fit and fractional anisotropy analyses.Results: Raw DWI data were preprocessed and quality checked with the proposed pipeline and demonstrated improved SNRs; physiologic intensity ratios; corrected susceptibility‐, eddy current‐, and motion‐induced artifacts; imputed signal‐lost slices; and improved tensor fits. The pipeline identified incorrect gradient configurations and file‐type conversion errors and was shown to be effective on externally available datasets.Conclusions: The proposed pipeline is a single integrated pipeline that combines established diffusion preprocessing tools from major MRI‐focused software packages with intuitive QA.Keywords
All Related Versions
Funding Information
- National Institute of General Medical Sciences (5T32GM007347)
- National Institute of Neurological Disorders and Stroke (5R01NS108445, 5R01NS110130)
- National Institute of Biomedical Imaging and Bioengineering (5R01EB017230, 5T32EB001628)
- National Center for Research Resources (1UL1RR024975)
- Division of Information and Intelligent Systems (1452485)
This publication has 63 references indexed in Scilit:
- Simultaneous Analysis and Quality Assurance for Diffusion Tensor ImagingPLOS ONE, 2013
- Fractional anisotropy of cerebral white matter and thickness of cortical gray matter across the lifespanNeuroImage, 2011
- An Introduction to Diffusion Tensor Image AnalysisNeurosurgery Clinics of North America, 2011
- Interactive Diffusion Tensor Tractography Visualization for Neurosurgical PlanningNeurosurgery, 2011
- Diffusion imaging in multiple sclerosis: research and clinical implicationsNMR in Biomedicine, 2010
- Symmetric diffeomorphic image registration with cross-correlation: Evaluating automated labeling of elderly and neurodegenerative brainMedical Image Analysis, 2008
- Tract probability maps in stereotaxic spaces: Analyses of white matter anatomy and tract-specific quantificationNeuroImage, 2008
- Reproducibility of quantitative tractography methods applied to cerebral white matterNeuroImage, 2007
- The Human Connectome: A Structural Description of the Human BrainPLOS Computational Biology, 2005
- Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithmIEEE Transactions on Medical Imaging, 2001