Genital tract infections associated with the intrauterine contraceptive device can be reduced by inserting the threads into the uterine cavity
Authors:
- 19 August 1992
- journal article
- clinical trial
- Published by Wiley in BJOG: An International Journal of Obstetrics & Gynaecology
- Vol. 99 (8) , 676-679
Abstract
Objective To study the influence of the position of the threads of an intrauterine contraceptive device (IUCD) on the development of genital tract infection.Design A multicentre randomized controlled trial. Subjects Women requesting an IUCD.Interventions The women were randomized to be fitted with an IUCD either with the threads contained in the uterine cavity (threads‐up group) (n= 208) or passing through the cervix to the vagina in the usual way (threads‐down group) (n= 237). Multiple centre study with follow‐up at three months, 1 and 2 years. At the final visit ‘missing’ threads were retrieved using a disposable instrument (RetrievetteR).Main outcome measures The occurrence of infection in the lower or upper genital tract.Results 63 women in the threads‐up group and 78 in the threads‐down groups dropped out. Previous gynaecological infection was reported by 21 and 48 women in the threads‐up and threads‐down group, respectively (odds ratio 0.44, 95% CI 0.24 to 0.79), 21 and 53 subjects had signs of infection at gynaecological examination (odds ratio 0.39,95% CI 0.21 to 0.69) and a wet‐smear was pathological in 33 and 79 (odds ratio 0.38, 95% CI 0.23 to 0.61). In the threads‐up group the vaginal pH was also lower at the final check up after 2 years. Spontaneous descent of the threads occurred in 11% of the threads‐up group and in six women in the threads‐down group the threads were in the cervix. In 93 women the threads were easily retrieved by means of the RetrievetteR, four women insisted on the threads remaining in the uterus and in 18 thread removal was performed under local or general anaesthesia.Conclusions Infectious complications in women using an IUCD are more frequent if the threads lead from the uterine cavity to the vagina. This problem can be reduced by inserting the threads so that they remain entirely within the uterine cavity, a feasible procedure now that an effective instrument for IUCD thread retrieval is available.Keywords
This publication has 13 references indexed in Scilit:
- Randomised comparative study in 217 women of three disposable plastic IUCD thread retrieversBJOG: An International Journal of Obstetrics & Gynaecology, 1992
- Microbial colonization of tailed and tailless intrauterine contraceptive devices: Influence of the mode of insertion in the rabbitAmerican Journal of Obstetrics and Gynecology, 1986
- A Solution to the Problem of “Missing” Iud threadsActa Obstetricia et Gynecologica Scandinavica, 1986
- THE BACTERIOLOGY OF THE CERVIX AND UTERUSBJOG: An International Journal of Obstetrics & Gynaecology, 1977
- Letter: Transport of bacteria by the dalkon shield tailJAMA, 1976
- A Study of the Intrauterine Contraceptive Device with and without an Extracervical Appendage or TailFertility and Sterility, 1970
- Sterility of the uterine cavityAmerican Journal of Obstetrics and Gynecology, 1967
- The intrauterine device: A bacteriologic study of the endometrial cavityAmerican Journal of Obstetrics and Gynecology, 1966
- Quantitative immunologic assay of human chorionic gonadotropin in normal and abnormal pregnanciesAmerican Journal of Obstetrics and Gynecology, 1966
- The Margulies intrauterine contraceptive deviceAmerican Journal of Obstetrics and Gynecology, 1965