Boundaries of Mass Resolution in Native Mass Spectrometry
- 4 April 2014
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 25 (6) , 906-917
Abstract
Over the last two decades, native mass spectrometry (MS) has emerged as a valuable tool to study intact proteins and noncovalent protein complexes. Studied experimental systems range from small-molecule (drug)–protein interactions, to nanomachineries such as the proteasome and ribosome, to even virus assembly. In native MS, ions attain high m/z values, requiring special mass analyzers for their detection. Depending on the particular mass analyzer used, instrumental mass resolution does often decrease at higher m/z but can still be above a couple of thousand at m/z 5000. However, the mass resolving power obtained on charge states of protein complexes in this m/z region is experimentally found to remain well below the inherent instrument resolution of the mass analyzers employed. Here, we inquire into reasons for this discrepancy and ask how native MS would benefit from higher instrumental mass resolution. To answer this question, we discuss advantages and shortcomings of mass analyzers used to study intact biomolecules and biomolecular complexes in their native state, and we review which other factors determine mass resolving power in native MS analyses. Recent examples from the literature are given to illustrate the current status and limitations. FigureKeywords
This publication has 74 references indexed in Scilit:
- Mass spectrometry reveals synergistic effects of nucleotides, lipids, and drugs binding to a multidrug resistance efflux pumpProceedings of the National Academy of Sciences of the United States of America, 2013
- Allosteric mechanisms can be distinguished using structural mass spectrometryProceedings of the National Academy of Sciences, 2013
- High Resolution Time-of-Flight Mass Analysis of the Entire Range of Intact Singly-Charged ProteinsAnalytical Chemistry, 2011
- Unit Mass Baseline Resolution for an Intact 148 kDa Therapeutic Monoclonal Antibody by Fourier Transform Ion Cyclotron Resonance Mass SpectrometryAnalytical Chemistry, 2011
- Limitation of Time-of-Flight Resolution in the Ultra High Mass RangeAnalytical Chemistry, 2011
- Fourier Transform Mass SpectrometryMolecular & Cellular Proteomics, 2011
- Performance Characteristics of a New Hybrid Quadrupole Time-of-Flight Tandem Mass Spectrometer (TripleTOF 5600)Analytical Chemistry, 2011
- Native Electrospray and Electron-Capture Dissociation FTICR Mass Spectrometry for Top-Down Studies of Protein AssembliesAnalytical Chemistry, 2011
- Native electrospray and electron-capture dissociation in FTICR mass spectrometry provide top-down sequencing of a protein component in an intact protein assemblyJournal of the American Society for Mass Spectrometry, 2010
- Mass spectrometry reveals modularity and a complete subunit interaction map of the eukaryotic translation factor eIF3Proceedings of the National Academy of Sciences of the United States of America, 2008