A challenging path to rational and harmonised international regulation of indoor radon
- 24 May 2023
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (8-9) , 1047-1055
Abstract
The main trends of indoor radon regulation in Europe are expressed through the standard ISO 11665-8. This standard, however, ignores the short-term tests (2–7 days in practice)—the main tests in the USA, and instead requires conducting long-term tests only (2–12 months)—without any justification. Moreover, the temporal (key) uncertainty of indoor radon is ignored altogether, a fact that does not allow the assessment of a room’s conformity with a normative at a given reliability (usually 95%). Thus, the current international regulation is neither harmonised nor rational. This paper reports the interim results of storming discussions within the ISO 11665-8 Focus Group, in charge of revising the aforementioned standard. Proposed are the rational criterion for conformity assessment of a room with a normative for both short- and long-term measurements, as well as the indicative values and the algorithm for determining indoor radon temporal uncertainty depending on the measurement duration.Keywords
This publication has 19 references indexed in Scilit:
- The history, development and the present status of the radon measurement programme in the United States of AmericaRadiation Protection Dosimetry, 2015
- Radon remediation and prevention status in 23 European countriesRadiation Protection Dosimetry, 2013
- Seasonal variation of radon concentrations in UK homesJournal of Radiological Protection, 2012
- Seasonal indoor radon concentration in FYR of MacedoniaRadiation Measurements, 2011
- Radon: exploring the log-normal mysteryJournal of Environmental Radioactivity, 2010
- On radon surveys: Design and data interpretationRadiation Measurements, 2009
- Seasonal changes in radon concentrations in buildings in the region of northeastern PolandJournal of Environmental Radioactivity, 2004
- Temporal Variation of Radon Levels in Houses and Implications for Radon Measurement StrategiesRadiation Protection Dosimetry, 2001
- Studies on temporal variations of radon in Swedish single-family housesEnvironment International, 1996
- Spatial and Temporal Indoor Radon VariationsHealth Physics, 1992