CSF gusher in cochlear implantation: The risk of missing CT evidence of a cochlear base defect in the presence of otherwise normal cochlear anatomy
Authors:
- Cavid CabbarzadeCCCavid Cabbarzade
- Levent SennarogluLSLevent Sennaroglu
- Nilda SüslüNSNilda Süslü
- 1 July 2014
- journal article
- case report
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 16 (4) , 233-236
Abstract
Intraoperative cerebrospinal fluid (CSF) leakages from the cochleostomy site - known as gushers - are a serious complication of cochlear implantation surgery in cases of congenital deafness. They occur as the result of abnormal communication between CSF in the internal auditory canal and perilymph in the cochlea. Gushers are well recognized as occurring in a proportion of cases in which there is a clearly visible congenital malformation of the cochlea. In this report, we describe two cases in which pre-operative computed tomography (CT) scanning of the cochlea was initially reported as normal but gushers occurred during cochlear implant surgery. In both cases, more detailed review of the CT scans (peroperatively in the first case, pre-operatively in the second case) showed a defect at the cochlear base, in the absence of any other cochlear malformation. The aim of this paper is to draw attention to the risk of missing this abnormality and to encourage careful inspection of the cochlear base on CT scans in all cases, even when the rest of the cochlear appears normal.Keywords
This publication has 10 references indexed in Scilit:
- Cochlear Implantation in Inner Ear Malformations — A Review ArticleCochlear Implants International, 2010
- Cochlear Implantation in China: Review of 1,237 Cases with an Emphasis on ComplicationsORL, 2009
- Surgical Results of Cochlear Implantation in Malformed CochleaOtology & Neurotology, 2006
- Preoperative Computed Tomography May Fail to Detect Patients at Risk for Perilymph GusherEar, Nose & Throat Journal, 2005
- CSF gusher in cochlear implantationCochlear Implants International, 2004
- Simple Method to Control a Cerebrospinal Fluid Gusher During Cochlear Implant SurgeryOtology & Neurotology, 2004
- Komplikationen der Cochlear Implant-Chirurgie bei Kindern und Erwachsenen1Laryngo-Rhino-Otologie, 1999
- Cochlear Implantation in Patients With Cochlear MalformationsJAMA Otolaryngology–Head & Neck Surgery, 1995
- Enlargement of the cochlear aqueduct: Fact or fiction?Otolaryngology–Head and Neck Surgery, 1993
- Type II collagen-induced otospongiosis-like lesions in ratsAmerican Journal of Otolaryngology, 1986