Two sampling methods for the Petri dish detection of airborne fungi
Open Access
- 1 September 2011
- journal article
- research article
- Published by Taylor & Francis in Grana
- Vol. 50 (3) , 202-207
Abstract
Burkard personal samplers for Petri dishes use two air throughput devices, either with a sieve or with a funnel, for monitoring of airborne fungi concentration. These two different methods have been compared in a comparative study. The two personal traps used for comparison were run simultaneously, one equipped with a sieve and one with a funnel only. Possible correlations with rainfall, temperature, wind speed, and relative humidity were studied. The average concentrations were 74 and 339 colony forming units/m3 (a factor of 4.6 difference) for the funnel and sieve devices, respectively. More than 70 taxa of airborne fungi were identified. The four most important genera in decreasing order of concentration were Cladosporium, Alternaria, Penicillium, and Aspergillus, the last two present in similar concentration. A significant negative correlation with wind speed was detected. Statistical analysis (ANOVA) revealed significant differences between the two sampler types except for Alternaria. In conclusion, the sampler with a sieve provides more colonies than the same sampler with a funnel. Both kinds of samplers are affected by wind speed, with the capture of airborne fungi propagules being reduced as the speed increases.Keywords
This publication has 25 references indexed in Scilit:
- Exposure to indoor fungi in different working environments: A comparative studyAerobiologia, 2010
- Use of personal sporetraps to complement continuous aerobiological monitoringGrana, 2010
- Fungi associated with three houses in Havana (Cuba)Grana, 2002
- Comparative performance of impactor air samplers for quantification of fungal contaminationJournal of Hospital Infection, 2001
- Laboratory evaluation of a new aerobiological sampler for use in the AntarcticJournal of Aerosol Science, 1997
- Sampling bioaerosols in plant pathologyJournal of Aerosol Science, 1997
- New aerosol sampler with low wind sensitivity and good filter collection uniformityAtmospheric Environment, 1995
- Performance of bioaerosol samplers: collection characteristics and sampler design considerationsAtmospheric Environment. Part A. General Topics, 1992
- Performance of the surface air system air samplersJournal of Hospital Infection, 1985
- The Assessment of Aerosol Concentration by Means of the Andersen SamplerJournal of Applied Bacteriology, 1970