Analytical Bit-Error Model of NAND Flash Memories for Dosimetry Application
- 8 November 2021
- journal article
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (3) , 478-484
Abstract
In this article, we provide an analytical model for the total ionizing dose (TID) effects on the bit error statistics of commercial flash memory chips. We have validated the model with experimental data collected by irradiating several commercial NAND flash memory chips from different technology nodes. We find that our analytical model can project bit errors at higher TID values [~20 krad (Si)] from measured data at lower TID values [<1 krad (Si)]. Based on our model and the measured data, we have formulated basic design rules for using a commercial flash memory chip as a dosimeter. We discuss the impact of NAND chip-to-chip variability, noise margin, and the intrinsic errors on the dosimeter design using detailed experimentation.Keywords
Funding Information
- U.S. Department of Energy (DOE), Office of Nuclear Energy under DOE Idaho Operations Office
- Nuclear Science User Facilities Experiment (DE-AC07-051D14517)
- National Science Foundation (1929099)
This publication has 24 references indexed in Scilit:
- Floating Gate Dosimeter Suitability for Accelerator-like EnvironmentsIEEE Transactions on Nuclear Science, 2017
- Error characterization and mitigation for 16nm MLC NAND flash memory under total ionizing dose effect2016
- The Dosimetric Performance of RADFETs in Radiation Test Beams2007
- Total-Ionizing-Dose Effects in Modern CMOS TechnologiesIEEE Transactions on Nuclear Science, 2006
- Improvements in resolution and dynamic range for FGMOS dosimetryIEEE Transactions on Nuclear Science, 2005
- A floating gate MOSFET dosimeter requiring no external bias supply2002
- Dosimetry based on the erasure of floating gates in the natural radiation environments in spaceIEEE Transactions on Nuclear Science, 1998
- Radiation response of floating gate EEPROM memory cellsIEEE Transactions on Nuclear Science, 1989
- RADFET: A review of the use of metal-oxide-silicon devices as integrating dosimetersInternational Journal of Radiation Applications and Instrumentation. Part C. Radiation Physics and Chemistry, 1986
- The Development of an MOS Dosimetry Unit for Use in SpaceIEEE Transactions on Nuclear Science, 1978