Abstract
Local anesthesia is valuable because it has the least impact on the homeostasis of the animal's body, so its use reduces the risk of complications during and after surgery. The areas of the animal's body in which the most effective performance of conduction blockades are the limbs, as well as the head, since these areas innervate a number of large nerves. The article describes the determination of the effectiveness of neurostimulation during conduction blockades in the head area of the maxillary nerve, and in the thoracic limb area of the radial, ulnar, median and musculocutaneous nerves in dogs during surgical interventions in the area of innervation by the corresponding nerves. The study was conducted on 10 dogs with pathological processes in the head and thoracic limb areas that were admitted to the Department of Veterinary Surgery and Reproductive Medicine of the BTU in the period 2020-2023. All conduction blockades were performed using the Stimuplex NHS 12 electroneurostimulator and insulated needles, which allow determining the position of the nerve, and the introduction of a local anesthetic. The indications for surgical interventions were fractures, wounds, neoplasms in the area of the upper jaw and thoracic limb distal to the wrist. Before performing local anesthesia, the animals were premedicated with neuroleptics, followed by the introduction of thiopenate intravenously in the minimum dose that ensured the animal's loss of consciousness. A 2% solution of lidocaine hydrochloride (Brovapharma) was used as a local anesthetic. As a result of the studies, the high efficiency of neurostimulation for performing conduction blockade of the maxillary nerve in the head area, as well as the radial, musculocutaneous, median and ulnar nerves in the thoracic limb area, which makes it possible to perform surgical intervention. The recommended parameters of neurostimulation using the “Stimuplex HNS 12” device are as follows: pulse length – 0.3 ms, frequency – 1 Hz, current strength during maxillary nerve blockade was from 0.28 to 0.32 mA, during limb nerve blockade – 0.4 mA. The use of conductive blockades allows to achieve complete loss of sensitivity of the operated area of the body in most animals, which significantly reduces the need for additional anesthetics. The procedure is safe, since the vital signs of the animals remained stable during the operations, and recovery from anesthesia was without complications.

This publication has 15 references indexed in Scilit: