Minimum number of basis projections for caries detection with local CT
Authors:
- An van DaatselaarADAn van Daatselaar
- DA TyndallDTDA Tyndall
- H VerheijHVH Verheij
- Pf van der SteltPSPf van der Stelt
- 1 November 2004
- journal article
- research article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 33 (6) , 355-360
Abstract
To investigate the relationship between the number of basis projections for local computed tomography (CT) and the detection of proximal caries and to find a minimum number of projections needed to maintain diagnostic accuracy. We presented observers (n = 12) with stacks of both axial and vertical CT slices of 23 extracted teeth placed in a dry human mandible. The slices were prepared with 14, 20, 33 and 100 basis projections. The observers scored the proximal surfaces for the presence of caries on a 1-5 confidence scale. The performance of the varying number of projections was compared with conventional digital radiographs. The performance of all four CT modalities was significantly better than conventional radiographs (P = 0.005 to P = 0.021) and showed a consistent increase with the number of projections. Diagnostic performance depended significantly on lesion depth (P = 0.00), but not on observer. We conclude that the number of CT projections used can be reduced at least to 20 with the diagnostic performance still markedly better than that of conventional film, provided that the observer can make use of both axial and vertical stacks of CT slices.Keywords
This publication has 8 references indexed in Scilit:
- Effect of number of projections on image quality of local CTDentomaxillofacial Radiology, 2004
- Detection of caries with local CTDentomaxillofacial Radiology, 2003
- Feasibility of local CT of dental tissuesDentomaxillofacial Radiology, 2003
- Influence of the number of basis images and projection array on caries detection using tuned aperture computed tomography (TACT).Dentomaxillofacial Radiology, 2002
- The effect of the number of iterative restorations on tuned aperture computed tomography for approximal caries detectionDentomaxillofacial Radiology, 2001
- Scanning resolution and the detection of approximal cariesDentomaxillofacial Radiology, 2001
- Two- and three-dimensional imaging modalities for the detection of caries. A comparison between film, digital radiography and tuned aperture computed tomography (TACTTM)Dentomaxillofacial Radiology, 1999