Abstract
Background: The current study reports measurements of activity concentrations of radon (222Rn) and thoron (220Rn) in dwellings, followed by inhalation dose assessment of the public, and then by the development of regulation and the national radon action plan (NRAP) in Cameroon.Materials and Methods: Radon, thoron, and thoron progeny measurements were carried out from 2014 to 2017 using radon-thoron discriminative detectors (commercially RADUET) in 450 dwellings and thoron progeny monitors in 350 dwellings. From 2019 to 2020, radon track detectors (commercially RADTRAK) were deployed in 1,400 dwellings. It was found that activity concentrations of radon range in 1,850 houses from 10 to 2,620 Bq/m3 with a geometric mean of 76 Bq/m3.Results and Discussion: Activity concentrations of thoron range from 20 to 700 Bq/m3 with a geometric mean of 107 Bq/m3. Thoron equilibrium factor ranges from 0.01 to 0.6, with an arithmetic mean of 0.09 that is higher than the default value of 0.02 given by UNSCEAR. On average, 49%, 9%, and 2% of all surveyed houses have radon concentrations above 100, 200, and 300 Bq/m3, respectively. The average contribution of thoron to the inhalation dose due to radon and thoron exposure is about 40%. Thus, thoron cannot be neglected in dose assessment to avoid biased results in radio-epidemiological studies. Only radon was considered in the drafted regulation and in the NRAP adopted in October 2020. Reference levels of 300 Bq/m3 and 1,000 Bq/m3 were recommended for dwellings and workplaces.Conclusion: Priority actions for the coming years include the following: radon risk mapping, promotion of a protection policy against radon in buildings, integration of the radon prevention and mitigation into the training of construction specialists, mitigation of dwellings and workplaces with high radon levels, increased public awareness of the health risks associated with radon, and development of programs on the scientific and technical aspects.Keywords
Funding Information
- International Atomic Energy Agency (CMR9009)
- Japanese Society for the Promotion of Science (26305021)
- Ministry of Scientific Research and Innovation, Cameroon (BIP 2015-2020)
This publication has 21 references indexed in Scilit:
- ICRP Publication 137: Occupational Intakes of Radionuclides: Part 3Annals of the ICRP, 2017
- Characteristic of thoron ( 220 Rn) in environmentApplied Radiation and Isotopes, 2017
- A comparison of the dose from natural radionuclides and artificial radionuclides after the Fukushima nuclear accidentJournal of Radiation Research, 2016
- Radon-thoron discriminative measurements in the high natural radiation areas of southwestern CameroonJournal of Environmental Radioactivity, 2015
- Preliminary Experiments Using a Passive Detector for Measuring Indoor 220Rn Progeny Concentrations with an Aerosol ChamberHealth Physics, 2015
- Natural radiation exposure to the public in the oil-bearing Bakassi Peninsula, CameroonRadioprotection, 2015
- Indoor radon measurements in the uranium regions of Poli and Lolodorf, CameroonJournal of Environmental Radioactivity, 2014
- Lung Cancer Risk from Radon and Progeny and Statement on RadonAnnals of the ICRP, 2010
- Up-to-date radon-thoron discriminative detector for a large scale surveyReview of Scientific Instruments, 2005
- Estimation of Thoron Progeny Concentrations in Dwellings with Their Deposition Rate Measurements.Japanese Journal of Health Physics, 2000