Limited-Open Achilles Tendon Repair Using Locking Sutures Versus Nonlocking Sutures
- 20 March 2014
- journal article
- research article
- Published by SAGE Publications in Foot & Ankle International
- Vol. 35 (6) , 612-618
Abstract
Several limited-open Achilles tendon repair techniques that use locking or nonlocking sutures have been developed, but direct comparisons of in vitro mechanical properties have not yet been reported in the literature. It was our hypothesis that loads applied to the repaired Achilles tendon would be better resisted by limited-open techniques that use locking stitches compared with limited-open repairs that use nonlocking stitches. The Achilles tendons of 31 fresh-frozen cadaver lower limbs were incised 4 cm proximal to the calcaneal insertion. Tendons were then repaired using 1 of 2 limited-open Achilles tendon repair tools, one using 3 nonlocking sutures and the other using a combination of locking and nonlocking sutures. Repaired specimens were cycled to 1000 cycles from 20 to 100 N and from 20 to 190 N followed by a single load to failure test. Nonparametric analyses were performed to compare the number of cycles to gapping and total load to failure between the 2 repair techniques. During cyclic loading, more cycles occurred prior to detection of 2-mm and 9.5-mm gaps in the locking suture construct compared with the nonlocking suture construct (P = .012 and P = .005, respectively). There was no difference in the number of cycles to a gap of 5 mm (P = .053). The locking suture construct also resisted a significantly greater load to failure compared with the nonlocking suture construct (P < .001; median 385.0 and 299.6 N, respectively). Limited-open repair techniques using locking sutures provided greater construct strength under both cyclic and ultimate loads compared with a repair technique that used only nonlocking sutures. Limited-open Achilles tendon repairs using locking sutures are better able to resist forces simulating early accelerated rehabilitation than repairs using nonlocking sutures.Keywords
This publication has 18 references indexed in Scilit:
- Is Percutaneous Repair Better Than Open Repair in Acute Achilles Tendon Rupture?Clinical Orthopaedics and Related Research, 2012
- Biomechanical Comparison of the Achillon® Tendon Repair System and the Krackow Locking Loop TechniqueFoot & Ankle International, 2011
- The effects of multiple freeze–thaw cycles on the biomechanical properties of the human bone‐patellar tendon‐bone allograftJournal of Orthopaedic Research, 2011
- Open Versus Minimal Invasive Repair With Achillon DeviceFoot & Ankle International, 2009
- Achilles tendon repair: Achillon system vs. Krackow suture: An anatomic in vitro biomechanical studyClinical Biomechanics, 2008
- Percutaneous versus Open Tendo Achillis RepairFoot & Ankle International, 2004
- Treatment of Acute Achilles Tendon Ruptures A Systematic Overview and MetaanalysisClinical Orthopaedics and Related Research, 2002
- Limited Open Repair of Achilles Tendon RupturesJournal of Bone and Joint Surgery, 2002
- The relative stress on the Achilles tendon during ambulation in an ankle immobiliser: implications for rehabilitation after Achilles tendon repairBritish Journal of Sports Medicine, 2001
- Achilles Tendon Rupture Repair: Biomechanical Comparison of the Triple Bundle Technique versus the Krakow Locking Loop TechniqueFoot & Ankle International, 2000