Abstract
(1) Background: Traumatic brain injuries (TBI) result in high fatality and lifelong disability rates. Two of the primary biomarkers in assessing TBI are intracranial pressure (ICP) and brain oxygenation. Both are assessed using standalone techniques, out of which ICP can only be assessed utilizing invasive techniques. The motivation of this research is the development of a non-invasive optical multimodal monitoring technology for ICP and brain oxygenation which will enable the effective management of TBI patients. (2) Methods: a multiwavelength optical sensor was designed and manufactured so as to assess both parameters based on the pulsatile and non-pulsatile signals detected from cerebral backscatter light. The probe consists of four LEDs and three photodetectors that measure photoplethysmography (PPG) and near-infrared spectroscopy (NIRS) signals from cerebral tissue. (3) Results: The instrumentation system designed to acquire these optical signals is described in detail along with a rigorous technical evaluation of both the sensor and instrumentation. Bench testing demonstrated the right performance of the electronic circuits while a signal quality assessment showed good indices across all wavelengths, with the signals from the distal photodetector being of highest quality. The system performed well within specifications and recorded good-quality pulsations from a head phantom and provided non-pulsatile signals as expected. (4) Conclusions: This development paves the way for a multimodal non-invasive tool for the effective assessment of TBI patients.Keywords
This publication has 23 references indexed in Scilit:
- Low-Power Photoplethysmogram Acquisition Integrated Circuit with Robust Light Interference CompensationSensors, 2015
- Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood PerfusionIEEE Transactions on Biomedical Engineering, 2015
- Absolute and Trend Accuracy of a New Regional Oximeter in Healthy Volunteers During Controlled HypoxiaAnesthesia & Analgesia, 2014
- Systolic Peak Detection in Acceleration Photoplethysmograms Measured from Emergency Responders in Tropical ConditionsPLOS ONE, 2013
- Multimodality Monitoring in the Neurointensive Care Unit: A Special Perspective for Patients with StrokeJournal of Stroke, 2013
- Biocompatible, High Precision, Wideband, Improved Howland Current Source With Lead-Lag CompensationIEEE Transactions on Biomedical Circuits and Systems, 2012
- Impact of Extracranial Contamination on Regional Cerebral Oxygen SaturationAnesthesiology, 2012
- Experimental investigation of NIRS spatial sensitivityBiomedical Optics Express, 2011
- Two-Stage Approach for Detection and Reduction of Motion Artifacts in Photoplethysmographic DataIEEE Transactions on Biomedical Engineering, 2010
- Noninvasive pulse oximetry utilizing skin reflectance photoplethysmographyIEEE Transactions on Biomedical Engineering, 1988