An installed flap on a flat plate wing is proposed to enhance the oscillating wing energy harvester’s power extraction performance. Numerical simulations are performed in the Reynolds number 5 × 105 to compare the oscillating wing energy harvester’s power extraction performance with and without a flap. A flap length of 20% of chord length and flap maximum pitch angles of 5°, 15°, 25°, 35°, and 45° are simulated for the oscillating wing with a flap. The oscillating wing’s maximum pitch angle is 75°, and the wing and flap’s pitch motion is sinusoidal. Numerical results showed that the incoming fluid deflected and increased its momentum change through the flap, increasing the pushing force on the wing and increasing with the increase in the flap’s maximum pitch angle. The results showed a 15.6% enhancement in power extraction performance of the oscillating wing with a 35° flap maximum pitch angle compared to a flat plate wing. The maximum wing pitch angles of 70° and 65° and varied flap maximum pitch angles are also simulated. The maximum power output obtained is around 19% with 70° wing and 35° flap maximum pitch angles compared to the flat plate wing.