RCU2 — The ALICE TPC readout electronics consolidation for Run2
Open Access
- 1 December 2013
- journal article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 8 (12) , C12032
Abstract
This paper presents the solution for optimization of the ALICE TPC readout for running at full energy in the Run2 period after 2014. For the data taking with heavy ion beams an event readout rate of 400 Hz with a low dead time is envisaged for the ALICE central barrel detectors during these three years. A new component, the Readout Control Unit 2 (RCU2), is being designed to increase the present readout rate by a factor of up to 2.6. The immunity to radiation induced errors will also be significantly improved by the new design.Keywords
This publication has 8 references indexed in Scilit:
- The New Generation of the CERN Accelerator Radiation Monitoring System for ElectronicsIEEE Transactions on Nuclear Science, 2013
- Overview of Recent ALICE ResultsNuclear Physics A, 2013
- First measurement of single event upsets in the readout control FPGA of the ALICE TPC detectorJournal of Instrumentation, 2011
- Development of a MicroTCA Carrier Hub for CMS at HL-LHCJournal of Instrumentation, 2010
- Upgrade of the ALICE-TPC read-out electronicsJournal of Instrumentation, 2010
- The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity eventsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Radiation-Tolerant, SRAM-FPGA Based Trigger and Readout Electronics for the ALICE ExperimentIEEE Transactions on Nuclear Science, 2008
- Total Ionizing Dose and Displacement-Damage Effects in MicroelectronicsMRS Bulletin, 2003