Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure
Authors:
- Marco BarbantiMBMarco Barbanti
- John G. WebbJWJohn G. Webb
- Claudia TamburinoCTClaudia Tamburino
- Nicolas M. Van MieghemNMNicolas M. Van Mieghem
- Raj R. MakkarRMRaj R. Makkar
- Nicolò PiazzaNPNicolò Piazza
- Azeem LatibAzeem Latib
- Jan-Malte SinningJSJan-Malte Sinning
- Kim Won-KeunKWKim Won-Keun
- Sabine BleizifferSBSabine Bleiziffer
- Francesco BedogniFBFrancesco Bedogni
- Samir KapadiaSKSamir Kapadia
- 1 September 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 9 (9)
Abstract
Background—: Transcatheter aortic valves can degenerate in a manner similar to surgical bioprostheses. Methods and Results—: Clinical and echocardiographic outcomes of patients who underwent redo transcatheter aortic valve replacement (TAVR) procedures >2 weeks post procedure were collected from 14 centers. Among 13 876 patients, 50 (0.4%) underwent redo TAVR procedure at participating centers. Indications for redo TAVR were moderate–severe prosthetic aortic valve stenosis (n=10, 21.7%), moderate–severe central prosthetic aortic valve regurgitation (n=13, 28.3%), and moderate–severe paraprosthetic aortic valve regurgitation (n=25, 50.0%). The index TAVR was most commonly a Medtronic CoreValve (N=38, 76.0%), followed by Edwards SAPIEN-type valves (n=12, 24.0%) and Portico (n=1, 2.0%). The redo TAVR device was most commonly a CoreValve/Evolut R (n=29, 58.0%), followed by a SAPIEN-type valve (n=20,40.0%) or a Boston Lotus valve (n=1, 2.0%). In 40 patients (80.0%), redo TAVR was performed using the identical device type or that of the succeeding generation. Valve performance was uniformly good after redo TAVR (mean transvalvular gradient post redo TAVR: 12.5±6.1 mm Hg). At hospital discharge, all patients remained alive, with 1 nondisabling stroke (2.0%) and 1 life-threatening bleed (2.0%). Permanent pacemaker implantation was required in 3 out of 35 patients without a prior pacemaker (8.6%). Late survival was 85.1% at a median follow-up of 1589 days (range: 31–3775) after index TAVR and 635 days (range: 8–2460) after redo TAVR. Conclusions—: Redo TAVR for the treatment of postprocedural and late occurrence of paravalvular regurgitation and transcatheter aortic valve prosthesis failure seems to be safe, and it is associated with favorable acute and midterm clinical and echocardiographic outcomes.Keywords
This publication has 19 references indexed in Scilit:
- Transcatheter Aortic Valve Implantation in the United KingdomCirculation, 2015
- Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical ValvesJAMA, 2014
- CoreValve Degeneration With Severe Transvalvular Aortic Regurgitation Treated With Valve-in-Valve ImplantationJACC: Cardiovascular Interventions, 2014
- 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart DiseaseCirculation, 2014
- Edwards Sapien XT valve placement as treatment option for aortic regurgitation after transfemoral CoreValve implantation: a multicenter experienceClinical Research in Cardiology, 2013
- Determinants and Outcomes of Acute Transcatheter Valve-in-Valve Therapy or EmbolizationJACC, 2013
- 5-Year Outcome After Transcatheter Aortic Valve ImplantationJACC, 2013
- Updated Standardized Endpoint Definitions for Transcatheter Aortic Valve ImplantationJACC, 2012
- The Valve-in-Valve Technique for Treatment of Aortic Bioprosthesis MalpositionJACC, 2011
- Choice of Prosthetic Heart Valve in AdultsJACC, 2010