Characterizing the influence of skin pigmentation on pulse oximetry
Authors:
- Arjun PutchaAPArjun Putcha
- Kevin SchichleinKSKevin Schichlein
- Tien NguyenTNTien Nguyen
- Brayden DavisBDBrayden Davis
- Rachel ChoffinRCRachel Choffin
- Simran MalikSMSimran Malik
- Aastha SharmaASAastha Sharma
- Grace SosaGSGrace Sosa
- Sara SaffariSSSara Saffari
- Joseph RibaudoJRJoseph Ribaudo
- Jessica GuidiciJGJessica Guidici
- Robert LampmanRLRobert Lampman
Open Access
- 11 June 2025
- journal article
- general
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 2 (03) , 1-17
Abstract
SignificancePulse oximeters are frequently used in healthcare settings to noninvasively estimate blood oxygen levels in patients, in turn influencing clinical decision-making. However, numerous studies have found pulse oximeters consistently overestimate oxygen levels in patients of color, with this overestimation increasing as oxygen levels decline. Although some reports postulate skin pigmentation may be the source of bias, to our knowledge, the precise impact of skin pigmentation on pulse oximetry has not been elucidated.AimOur objective is to experimentally characterize the impact of skin pigmentation on pulse oximeters across a broad range of oxygen saturations and determine whether skin pigmentation can explain the observed pulse oximeter bias in patients of color.ResultsUsing a live porcine model, we experimentally demonstrate the impact of skin pigmentation on pulse oximeter calculation. In particular, we show that skin pigmentation attenuates the sensitivity of red-light absorption to changes in oxygen saturation and show that the pulse oximeter output is consequently attenuated in pigmented skin.ConclusionThe systematic animal experiments confirm the confounding impact of skin pigmentation on intermediate calculations of pulse oximetry, and validate existing clinical observations of pulse oximeter bias in patients of color.Keywords
Funding Information
- National Science Foundation (ECCS-2139659)
- National Institute of Health (1R01EB034332-01)
- North Carolina Biotechnology Center (2024-TRG-0030)
This publication has 56 references indexed in Scilit:
- Effect of skin tone on the accuracy of the estimation of arterial oxygen saturation by pulse oximetry: a systematic reviewBritish Journal of Anaesthesia, 2024
- LED light can falsify pulse oximetry readings via the stroboscopic effectPhysical and Engineering Sciences in Medicine, 2023
- Evaluation of Version 4 of the Emergency Severity Index in US Emergency Departments for the Rate of MistriageJAMA Network Open, 2023
- Racial and Ethnic Discrepancy in Pulse Oximetry and Delayed Identification of Treatment Eligibility Among Patients With COVID-19JAMA Internal Medicine, 2022
- Analysis of Discrepancies Between Pulse Oximetry and Arterial Oxygen Saturation Measurements by Race and Ethnicity and Association With Organ Dysfunction and MortalityJAMA Network Open, 2021
- Safety of light emitting diode‐red light on human skin: Two randomized controlled trialsJournal of Biophotonics, 2019
- In vivo investigation of ear canal pulse oximetry during hypothermiaJournal of Clinical Monitoring and Computing, 2017
- The thermal impact of phototherapy with concurrent super-pulsed lasers and red and infrared LEDs on human skinLasers in Medical Science, 2015
- Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO2 sensorMedical & Biological Engineering & Computing, 2012
- Simplification of the Pulmonary Embolism Severity Index for Prognostication in Patients With Acute Symptomatic Pulmonary EmbolismArchives of internal medicine (1960), 2010