Fatal cardiomyopathy after revision total hip replacement for fracture of a ceramic liner
Authors:
- 1 January 2013
- journal article
- case report
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 95-B (1) , 31-37
Abstract
Symptomatic cobalt toxicity from a failed total hip replacement is a rare but devastating complication. It has been reported following revision of fractured ceramic components, as well as in patients with failed metal-on-metal articulations. Potential clinical findings include fatigue, weakness, hypothyroidism, cardiomyopathy, polycythaemia, visual and hearing impairment, cognitive dysfunction, and neuropathy. We report a case of an otherwise healthy 46-year-old patient, who developed progressively worsening symptoms of cobalt toxicity beginning approximately six months following synovectomy and revision of a fractured ceramic-on-ceramic total hip replacement to a metal-on-polyethylene bearing. The whole blood cobalt levels peaked at 6521 µg/l. The patient died from cobalt-induced cardiomyopathy. Implant retrieval analysis confirmed a loss of 28.3 g mass of the cobalt–chromium femoral head as a result of severe abrasive wear by ceramic particles embedded in the revision polyethylene liner. Autopsy findings were consistent with heavy metal-induced cardiomyopathy. We recommend using new ceramics at revision to minimise the risk of wear-related cobalt toxicity following breakage of ceramic components. Cite this article: Bone Joint J 2013;95-B:31–7.Keywords
This publication has 39 references indexed in Scilit:
- Evidence-Based Understanding of Management Perils for Metal-on-Metal Hip Arthroplasty PatientsThe Journal of Arthroplasty, 2012
- Ceramic Bearings for Total Hip Arthroplasty Have High Survivorship at 10 YearsClinical Orthopaedics and Related Research, 2012
- Comparison of micro-computed tomography and laser scanning for reverse engineering orthopaedic component geometriesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2012
- State of the art in hard-on-hard bearings: how did we get here and what have we achieved?Expert Review of Medical Devices, 2011
- Severe Cobalt Intoxication Due to Prosthesis Wear in Repeated Total Hip ArthroplastyThe Journal of Arthroplasty, 2009
- PRESIDENTIAL GUEST LECTURE: Tribology of Alternative BearingsClinical Orthopaedics and Related Research, 2006
- Cobalt-chromium head wear following revision hip arthroplasty performed after ceramic fracture—a case reportActa Orthopaedica, 2006
- Recommendations for Chamber Quantification: A Report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, Developed in Conjunction with the European Association of Echocardiography, a Branch of the European Society of CardiologyJournal of the American Society of Echocardiography, 2005
- Massive metallosis after revision of a fractured ceramic head onto a metal headArchives of orthopaedic and trauma surgery, 2003
- Ceramic Femoral Head Retrieval DataClinical Orthopaedics and Related Research, 2000