Outcomes of Open Complex Ventral Hernia Repairs With Retromuscular Placement of Poly-4-Hydroxybutyrate Bioabsorbable Mesh
Authors:
- 16 October 2019
- journal article
- research article
- Published by SAGE Publications in Surgical Innovation
- Vol. 27 (1) , 32-37
Abstract
Purpose. Optimal technique and mesh selection still debated for complex ventral hernias. Limited data exists on bioabsorbable meshes in high-risk patients. We evaluated our experience. Methods. Retrospective review was conducted following institutional review board approval for ventral hernia repairs using a single bioabsorbable mesh between February 2014 and November 2017. Patient and hernia details characterized. Outcomes evaluated. Results. 20 ventral hernia repairs identified, 10 males, 10 females. Mean body mass index was 35 ± 7.4 kg/m2, and mean age 47 ± 13 years. Comorbid conditions were diabetes 35% and hypertension 40%. Fifty-five percent had American Society of Anesthesiologist scores of 3. Hernia Characteristics: Ventral Hernia Working Group Grade 3 hernias were 80%, and remainder grade 2. Forty percent of hernias were Centers for Disease Control class III, and remainder were class I and II. The mean defect size was 533 cm2 ± 500. Repair for prior open abdomens was 45%, recurrent hernias 20%, incisional 15%, incarcerated 10%, incisional with parastomal 5%, and primary ventral 5%. Concomitant bowel procedures in 8, (40%). All cases had retromuscular mesh placement (transversus abdominus release 65%, Rives-Stoppa 35%). Surgical site occurrences were 20% (surgical site infection 10%, seroma 10%). Overall hospital stay 5 ± 3 days. Ileus occurred in 20%. One postoperative death due to fatal arrhythmia. There were no recurrences with mean follow-up 21.1 months. Conclusions. Complex hernia repairs using bioabsorbable mesh were conducted in a small cohort of high-risk patients. These data demonstrate good outcomes with limited morbidity and mortality. There were no recurrences.Keywords
This publication has 27 references indexed in Scilit:
- A 5-Year Clinical Experience With Single-Staged Repairs of Infected and Contaminated Abdominal Wall Defects Utilizing Biologic MeshAnnals of Surgery, 2013
- Characterization of the Mechanical Strength, Resorption Properties, and Histologic Characteristics of a Fully Absorbable Material (Poly-4-hydroxybutyrate—PHASIX Mesh) in a Porcine Model of Hernia RepairISRN Surgery, 2013
- Transversus abdominis muscle release: a novel approach to posterior component separation during complex abdominal wall reconstructionThe American Journal of Surgery, 2012
- Prospective study of single-stage repair of contaminated hernias using a biologic porcine tissue matrix: The RICH StudySurgery, 2012
- The Impact of Smoking on Surgical OutcomesJournal of the American College of Surgeons, 2012
- Ventral Hernia Repair: Outcomes Change with Long-Term Follow-UpJSLS : Journal of the Society of Laparoscopic & Robotic Surgeons, 2012
- Incisional ventral hernias: Review of the literature and recommendations regarding the grading and technique of repairSurgery, 2010
- Preventing Surgical-Site Infections in Nasal Carriers ofStaphylococcus aureusNew England Journal of Medicine, 2010
- Non–Cross-Linked Porcine Acellular Dermal Matrices for Abdominal Wall ReconstructionPlastic and Reconstructive Surgery, 2010
- Long-term Follow-up of a Randomized Controlled Trial of Suture Versus Mesh Repair of Incisional HerniaAnnals of Surgery, 2004