Experimental Assessment of Peak Daylight Exposure Under Clear-Sky Conditions in Zenithally Lit Museum Rooms at 51° Latitude
Open Access
Abstract
This study investigates peak daylight exposure in zenithally lit museum rooms at 51° latitude through an experimental campaign using a 1:20 physical mock-up of a 12 × 12 × 6 m exhibition gallery space. Nine configurations of shading and light-transmitting elements (CSaLTE) were tested under real clear-sky conditions between June and October. To ensure a valid comparative analysis, indoor vertical illuminance (Ev) was measured at 15 min intervals and subsequently interpolated and normalised to a unified equinox-day solar geometry (06:00–18:00). This hybrid empirical-computational methodology allows for a direct performance comparison across different geometric arrangements regardless of their specific measurement dates. The results demonstrate that while traditional annual metrics are the standard, short-term illuminance peaks pose a severe and underexplored threat to conservation safety. Even the most light-attenuating diffusing-roof configurations produced short-term illuminance peaks and cumulative clear-sky exposures that are comparable in magnitude to commonly cited annual limits for highly light-sensitive materials, with several configurations recording extreme spikes surpassing the sensor’s 20,000 lx saturation limit. Stable, low-illuminance distributions were observed only in selected diffusing-roof arrangements (M05–M07), whereas direct-glazing systems (M01–M04) produced unsafe exposure patterns with high temporal variability and poor visual adaptation conditions. The study concludes that passive roof geometries alone are insufficient to ensure conservation-level safety without additional active filtering or adaptive control strategies, providing an experimentally grounded framework for designing zenithal daylighting systems in museum environments. The results are intended for relative peak-risk comparison under controlled clear-sky conditions rather than direct generalisation to whole-room annual conservation safety.Keywords
Funding Information
- Politechnika Wrocławska (F/2023/45420)
This publication has 17 references indexed in Scilit:
- Multi-objective optimization of daylighting systems for energy efficiency and thermal-visual comfort in buildings: a reviewBuilding and Environment, 2025
- Investigation into the daylight performance of expanded-metal shading through parametric design and multi-objective optimisation in JapanJournal of Building Engineering, 2022
- Application of climate-based daylight simulation to assess lighting conditions of space and artworks in historical buildings: the case study of cetacean gallery of the Monumental Charterhouse of CalciJournal of Cultural Heritage, 2020
- A Method for Optimizing Facades Design for Enhancing Daylight Distribution in Exhibition Spaces2020
- Multidisciplinary risk-based analysis for supporting the decision making process on conservation, energy efficiency, and human comfort in museum buildingsJournal of Cultural Heritage, 2016
- Light damage to selected organic materials in display cases: A study of different light sourcesStudies in Conservation, 2016
- Daylighting performance of sawtooth roofs of industrial buildingsLighting Research & Technology, 2003
- Diffuse fraction of UV radiation under partly cloudy skies as defined by the Automated Surface Observation System (ASOS)Journal of Geophysical Research: Atmospheres, 2003
- DAYLIGHT IN MUSEUM GALLERIES: EVALUATION USING SCALE MODELSStudies in Conservation, 1994
- Global transmissivity and diffuse fraction of solar radiation for clear and cloudy skies as measured and as predicted by bulk transmissivity modelsSolar Energy, 1985