Assessment and reproducibility of anterior chamber depth measurement with anterior segment optical coherence tomography compared with immersion ultrasonography
Authors:
- 1 March 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 33 (3) , 443-447
Abstract
To measure anterior chamber depth (ACD) with an anterior segment optical coherence tomography (AS-OCT) and a standard ultrasonic (US) axial scan (A-scan) device using an immersion technique and to assess repeatability, reproducibility, and correlations of the measurements. Department of Ophthalmology, Medical Health and Science Center, University of Debrecen, Debrecen, Hungary. Sixty healthy eyes of 41 patients were enrolled in a study. The central ACD was measured 5 times with AS-OCT (Visante, Carl Zeiss Meditec) using its chamber tool and 5 times with a US A-scan device (UltraScan Imaging System, Alcon Laboratories) using an immersion method. The measurements were performed consecutively by 2 independent observers. The mean ACD measured with AS-OCT was 3.12 mm +/- 0.33 (SD) by observer 1 and 3.11 +/- 0.33 mm by observer 2 (P = .78). The repeatability was 0.8% +/- 0.4% and 1.9% +/- 1.4%, respectively. The reproducibility was 0.23%. The reliability coefficient with AS-OCT was 99.6%. The mean ACD measured with immersion US A-scan was 2.98 +/- 0.33 mm by observer 1 and 2.95 +/- 0.34 mm by observer 2 (P = .68) . The repeatability was 6.4% +/- 3.8% by observer 1 and 8.5% +/- 4.9% by observer 2. The reproducibility was 0.88%. The reliability coefficient was 87.1% for US A-scan measurements. The difference between ACD values with AS-OCT and values with US A-scan was statistically significant (P = .02). The correlation (r) between AS-OCT and US A-scan was 0.732 (P<.0001) by observer 1 and 0.802 (P<.0001) by observer 2. Anterior chamber measurements were significantly deeper with AS-OCT than with US immersion A-scan. Repeatability of ACD measurements was better with AS-OCT than with immersion US, and reproducibility was equal with the 2 methods.Keywords
This publication has 25 references indexed in Scilit:
- Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgeryJournal of Cataract & Refractive Surgery, 2003
- Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyesJournal of Cataract & Refractive Surgery, 2003
- Multicenter biometry study of 1 pair of eyesJournal of Cataract & Refractive Surgery, 2001
- Clinical results using the Holladay 2 intraocular lens power formulaJournal of Cataract & Refractive Surgery, 2000
- Anterior Chamber Depth Measurement as a Screening Tool for Primary Angle-closure Glaucoma in an East Asian PopulationArchives of Ophthalmology (1950), 2000
- Biometry and Primary Angle-closure Glaucoma among Chinese, White, and Black PopulationsOphthalmology, 1997
- Intraocular lens power calculation with an improved anterior chamber depth prediction algorithmJournal of Cataract & Refractive Surgery, 1995
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 1992
- The accuracy of ultrasonic determination of axial length in pseudophakic eyesActa Ophthalmologica, 1989
- Theoretical approach to intraocular lens calculation using Gaussian opticsJournal of Cataract & Refractive Surgery, 1987