N-Terminal Pro-B-Type Natriuretic Peptide and B-Type Natriuretic Peptide-to-Troponin - Ratios for Differentiating Type 1 From Type 2 Myocardial Infarction: A HIGH-US Substudy
Authors:
- 25 September 2025
- journal article
- Published by Wolters Kluwer Health in Critical Pathways in Cardiology: A Journal of Evidence-Based Medicine
- Vol. 24 (4) , e0399
Abstract
Background: Differentiating type 1 myocardial infarction (T1-MI) from type 2 MI (T2-MI) remains a diagnostic challenge, even with the availability of high-sensitivity cardiac troponin assays. This study explored whether N-Terminal Pro-B-Type Natriuretic Peptide (NT-proBNP), BNP, and their respective ratios to troponin could enhance the ability to distinguish between these MI subtypes. Methods: As a High-Sensitivity Cardiac Troponin I Assays in the United States substudy, we examined data from 280 patients diagnosed with non-ST elevation MI (172 with T1-MI and 108 with T2-MI). We assessed NT-proBNP, BNP, high-sensitivity cardiac troponin I, and their ratios as potential discriminative biomarkers. Diagnostic accuracy was evaluated using receiver operating characteristic curves. Results: NT-proBNP levels were markedly elevated in T2-MI patients compared with those with T1-MI (mean: 10,327 ± 12,923 vs. 4675 ± 11,740 ng/L; P = 0.006). Conversely, high-sensitivity cardiac troponin I concentrations were higher in T1-MI (1.4 ± 5.1 vs. 0.5 ± 1.1 ng/L; P = 0.030). Notably, the NT-proBNP-to-troponin ratio was more than 3 times greater in T2-MI cases (94,880 ± 152,648 vs. 24,209 ± 78,727; P = 0.007). NT-proBNP alone demonstrated fair discriminatory capacity [area under the receiver operating characteristic curve (AUC) 0.717, 95% confidence interval (CI): 0.578–0.856], closely matching the NT-proBNP-to-troponin ratio (AUC: 0.720, 95% CI: 0.566–0.873). In contrast, BNP and the BNP-to-troponin ratio offered lower diagnostic values. Mean BNP levels were 505.4 ± 576.6 ng/L for those with T2-MI and 437.1 ± 738.8 ng/L for patients with T1-MI. BNP-to-troponin ratio showed a poor discrimination for the 2 MI types (AUC: 0.660; 95% CI: 0.532–0.789). Conclusions: Both NT-proBNP and its ratio to troponin show potential in differentiating T1-MI from T2-MI, reflecting distinct underlying pathophysiological processes. Given its comparable performance to the ratio, NT-proBNP alone may serve as a practical and cost-effective standalone marker. These findings support the hypothesis that incorporating NT-proBNP testing into routine clinical workflows may better inform the management of patients with suspected MI.Keywords
This publication has 13 references indexed in Scilit:
- 2022 AHA/ACC/HFSA Guideline for the Management of Heart FailureJACC, 2022
- Performance of Novel High-Sensitivity Cardiac Troponin I Assays for 0/1-Hour and 0/2- to 3-Hour Evaluations for Acute Myocardial Infarction: Results From the HIGH-US StudyAnnals of Emergency Medicine, 2020
- Cardiovascular Mortality After Type 1 and Type 2 Myocardial Infarction in Young AdultsJACC, 2020
- Clinical application of the 4th Universal Definition of Myocardial InfarctionEuropean Heart Journal, 2020
- The ratio of N-terminal pro-B-type natriuretic peptide to troponin I for differentiating acute coronary syndromeThe American Journal of Emergency Medicine, 2019
- Differentiating type 1 and 2 acute myocardial infarctions using the N-terminal pro B-type natriuretic peptide/cardiac troponin T ratioThe American Journal of Emergency Medicine, 2018
- THE RATIO OF N-TERMINAL PRO-BRAIN NATRIURETIC PEPTIDE TO HIGH SENSITIVITY CARDIAC TROPONIN TO DISTINGUISH TYPE 1 FROM TYPE 2 ACUTE MYOCARDIAL INFARCTIONJACC, 2018
- Troponin Testing in Patients Without Chest Pain or Electrocardiographic Ischemic ChangesThe American Journal of Medicine, 2017
- Discrimination of patients with type 2 myocardial infarctionEuropean Heart Journal, 2017
- The N-terminal Pro-BNP Investigation of Dyspnea in the Emergency department (PRIDE) studyThe American Journal of Cardiology, 2005