Towards robust glucose chemical exchange saturation transfer imaging in humans at 3 T: Arterial input function measurements and the effects of infusion time
Open Access
- 29 September 2021
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 35 (2) , e4624
Abstract
Dynamic glucose‐enhanced (DGE) magnetic resonance imaging (MRI) has shown potential for tumor imaging using D‐glucose as a biodegradable contrast agent. The DGE signal change is small at 3 T (around 1%) and accurate detection is hampered by motion. The intravenous D‐glucose injection is associated with transient side effects that can indirectly generate subject movements. In this study, the aim was to study DGE arterial input functions (AIFs) in healthy volunteers at 3 T for different scanning protocols, as a step towards making the glucose chemical exchange saturation transfer (glucoCEST) protocol more robust. Two different infusion durations (1.5 and 4.0 min) and saturation frequency offsets (1.2 and 2.0 ppm) were used. The effect of subject motion on the DGE signal was studied by using motion estimates retrieved from standard retrospective motion correction to create pseudo‐DGE maps, where the apparent DGE signal changes were entirely caused by motion. Furthermore, the DGE AIFs were compared with venous blood glucose levels. A significant difference (p = 0.03) between arterial baseline and postinfusion DGE signal was found after D‐glucose infusion. The results indicate that the measured DGE AIF signal change depends on both motion and blood glucose concentration change, emphasizing the need for sufficient motion correction in glucoCEST imaging. Finally, we conclude that a longer infusion duration (e.g. 3–4 min) should preferably be used in glucoCEST experiments, because it can minimize the glucose infusion side effects without negatively affecting the DGE signal change.Keywords
Funding Information
- National Institutes of Health (RO1 EB019934)
- Cancerfonden (CAN 2018/550, CAN 2018/468, CAN 2015/251)
- Vetenskapsrådet (2019–01162, 2017–00995, 2015–04170)
- Johns Hopkins University
- Lunds Universitet
This publication has 35 references indexed in Scilit:
- In vivo imaging of glucose uptake and metabolism in tumorsNature Medicine, 2013
- Natural D‐glucose as a biodegradable MRI contrast agent for detecting cancerMagnetic Resonance in Medicine, 2012
- Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protonsMagnetic Resonance in Medicine, 2010
- elastix: A Toolbox for Intensity-Based Medical Image RegistrationIEEE Transactions on Medical Imaging, 2009
- Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivoMagnetic Resonance in Medicine, 2007
- Chemical exchange saturation transfer imaging and spectroscopyProgress in Nuclear Magnetic Resonance Spectroscopy, 2006
- Model of the human vasculature for studying the influence of contrast injection speed on cerebral perfusion MRIMagnetic Resonance in Medicine, 2003
- Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithmIEEE Transactions on Medical Imaging, 2001
- A New Class of Contrast Agents for MRI Based on Proton Chemical Exchange Dependent Saturation Transfer (CEST)Journal of Magnetic Resonance, 2000
- Influence of glycogen on water proton relaxation timesMagnetic Resonance in Medicine, 1986