Determining the relative and absolute reliability of outcomes of physical performance tests for people undergoing hemodialysis is necessary to discriminate between the true effects of exercise interventions and the inherent variability of this cohort. The aims of this study were to assess the relative reliability of sit-to-stand-to-sit tests (the STS-10, which measures the time [in seconds] required to complete 10 full stands from a sitting position, and the STS-60, which measures the number of repetitions achieved in 60 seconds), the Six-Minute Walk Test (6MWT), the one-leg heel-rise test, and the handgrip strength test and to calculate minimal detectable change (MDC) scores in people undergoing hemodialysis. This study was a prospective, nonexperimental investigation. Thirty-nine people undergoing hemodialysis at 2 clinics in Spain were contacted. Study participants performed the STS-10 (n=37), the STS-60 (n=37), and the 6MWT (n=36). At one of the settings, the participants also performed the one-leg heel-rise test (n=21) and the handgrip strength test (n=12) on both the right and the left sides. Participants attended 2 testing sessions 1 to 2 weeks apart. High intraclass correlation coefficients (≥.88) were found for all tests, suggesting good relative reliability. The MDC scores at 90% confidence intervals were as follows: 8.4 seconds for the STS-10, 4 repetitions for the STS-60, 66.3 m for the 6MWT, 3.4 kg for handgrip strength (force-generating capacity), 3.7 repetitions for the one-leg heel-rise test with the right leg, and 5.2 repetitions for the one-leg heel-rise test with the left leg. Limitations A limited sample of patients was used in this study. The STS-16, STS-60, 6MWT, one-leg heel rise test, and handgrip strength test are reliable outcome measures. The MDC scores at 90% confidence intervals for these tests will help to determine whether a change is due to error or to an intervention.Keywords
This publication has 46 references indexed in Scilit:
- Exercise in End-Stage Renal DiseaseSeminars in Dialysis, 2010
- Progressive Exercise for Anabolism in Kidney Disease (PEAK)Journal of the American Society of Nephrology, 2007
- Effects of Resistance Exercise Training and Nandrolone Decanoate on Body Composition and Muscle Function among Patients Who Receive HemodialysisJournal of the American Society of Nephrology, 2006
- The effects of a low-to-moderate intensity pre-conditioning exercise programme linked with exercise counselling for sedentary haemodialysis patients in The Netherlands: results of a randomized clinical trialNephrology Dialysis Transplantation, 2004
- Effects of exercise training plus normalization of hematocrit on exercise capacity and health-related quality of lifeAmerican Journal of Kidney Diseases, 2002
- Exercise training in patients with end-stage renal disease on hemodialysis: Comparison of three rehabilitation programsJournal of Rehabilitation Medicine, 2002
- Cardiac effects of exercise rehabilitation in hemodialysis patientsInternational Journal of Cardiology, 1999
- Effects of physical training on heart rate variability in patients on hemodialysisThe American Journal of Cardiology, 1999
- Exercise Coaching and Rehabilitation Counseling Improve Quality of Life for Predialysis and Dialysis PatientsNephron, 1999
- Exercise Renal Rehabilitation Program: Psychosocial EffectsNephron, 1997